Item name
Command name
Command
Number
I/O output 9
72
39
I/O output 10
72
40
I/O output 11
72
41
Return command setting
1:OFF; 2: STABLE; 3: ZERO BAND; 4: FULL; 5: F. FLOW; 6: M. (Middle) FLOW; 7:
D. (Fine) FLOW; 8: OVER; 9: OK; 10: UNDER; 11: MIXING; 12: DISCHARGE (GATE
OPEN); 13: INFLOW FINISH; 15: DISCHARGE FINISH; 16: MIXING FINISH; 17:
NOZZLE DOWN (INSERT); 18: DURING MEASUREMENT; 19: MEASUREMENT
SEQUENCE ERROR; 20: CAP. EXCEEDED ERROR; 21: ERROR; 22: DURING TA-
RE WEIGHT; 23: CENTER OF ZERO; 24: GROSS WEIGHT DISPLAY; 25: NET
WEIGHT DISPLAY; 26: DURING HOLD; 77: SERVO ERROR
Command name
Command
Number Command name
I/O output logic (OUT1 ~ OUT7) 72
61
1: [Negative logic]; 2: [Positive
logic]; 100: I/O OUTPUT1; 101: I/
O OUTPUT2; 103: I/O OUTPUT3;
104: I/O OUTPUT4; 105: I/O
OUTPUT5; 106: I/O OUTPUT6;
107: I/O OUTPUT7
I/O output logic (OUT8 ~ OUT11) 72
62
1: [Negative logic]; 2: [Positive
logic]; 100: I/O OUTPUT 8; 101:
I/O OUTPUT 9; 103: I/O OUTPUT
10; 104: I/O OUTPUT 11
Read out commands
Item name
Command name
Com-
mand
Number Return command setting value
Zero key lock
72
51
1: EFFECTIVE; 2: INVALID
Gross/Net weight key lock 72
52
1: EFFECTIVE; 2: INVALID
Tara key lock
72
53
1: EFFECTIVE; 2: INVALID
Brand code key lock
72
54
1: EFFECTIVE; 2: INVALID
F key lock
72
55
1: EFFECTIVE; 2: INVALID
Menu key lock
72
56
1: EFFECTIVE; 2: INVALID
Calibration key lock
72
57
1: EFFECTIVE; 2: INVALID
I/O setting
Servo CALIB. key lock
72
58
1: EFFECTIVE; 2: INVALID
Control mode
73
02
1: Inlow mode; 2: Discharge mode; 3: Ex-
ternal input change
I/O setting
Comparison signal opera-
tion (Operation of Over,
OK and Under)
73
03
1: ANY TIME; 2: STABLE; 3: SYNC with inlow
inish; 4: HOLD at inlow inish
Weight Controller CSD-918
17 Options
EN-172
Minebea Intec
Содержание CSD-918 Series
Страница 239: ......