Writing set values
2
4
6
8
10
12
14
16
18
@
0
0
B
0
0
0
0
3
0
1
Terminator
Address
00 to 31
Space
Number
Command No.
Return
2
4
6
8
10
12
14
16
18
@
0
0
B
0
0
0
0
3
0
1
Terminator
Address
00 to 31
Set value
Number
Command No.
Return under abnormal conditions (For diferent set value ranges) (device → host)
6
6
8
4
2
@
0
0
E
R
1
3
Terminator
Address
00 ~ 31
Note:
-
The command number during write writing changes from [7*,] to [8 *], see
Chapter
-
The setting value is an integral value without a decimal point in the units described
in Chapter
.
Read out commands
Item na-
me
Command name
Command Num-
ber
Return command setting value
BRAND CODE
70
01
0 to 99
BRAND NAME
70
02
15 alphanumerical characters
FINAL
70
04
0 to 999 999
OVER
70
08
0 to 999 999
UNDER
70
09
0 to 999 999
ZERO BAND
70
10
0 to 999 999
FULL
70
11
0 to 999 999
A. F.F. COMPENSATION
70
12
0 to 999 999; 0: OFF for A.F.F. COMPENSATION
SUPPLEMENTARY FLOW
(Post-batching) TIME
70
13
0.00 to 99.99 s (Unit: 0.01 s)
JUDGE. AFTER S-FLOW
WAIT
70
14
0.00 to 99.99 s (Unit: 0.01 s)
BRAND
setting
BRAND ACCUM TOTAL
70
15
–99 999 999 to 99 999 999
Weight Controller CSD-918
17 Options
EN-168
Minebea Intec
Содержание CSD-918 Series
Страница 239: ......