Raw material
Programmable logic controller
Feed gate
Weighing hopper
Coarse/Middle/Fine flow
Discharge gate
Load cell
Container
Full amount output
Discharge mode
PLC
20.00 kg
-20.00 kg
Coarse
F
low
Middle
F
low
F
ine
F
low
2 Comparison signal operation (COMPARISON)
The operating condition of the comparison signal is selectable from [ANYTIME], [IN
STABLE MODE],[SYNC. WITH BATCH FIN] or [SYNC. BATCH FIN HOLD].
[SYNC. WITH BATCH FIN] is selectable as default.
3
Near zero (ZERO BAND) comparison operation (COMP.OF ZERO BAND)
The operation condition of near zero signal is selectable from [GROSS], [NET],
[comparison signal OFF], [ ? GROSS ? or ? NET ?].
Gross weight is selected as default.
4 FULL comparative operation (COMPARATIVE OF FULL)
The operating condition of [FULL] signal is selectable from [GROSS], [NET], [com-
parison signal OFF], [ ? GROSS ? or ? NET ?].
Gross weight is selected as default.
5 Saving Automatic free fall value (SAVE THE A.F.F.)
When the Brand is changed, the automatic free fall compensation value in the brand
before it changes is selectable from [NO MEMORIZE] or [MEMORIZE].
[NO MEMORIZE] is selected as default.
6 Safety check condition during the BATCH (BATCHING SAFETY CHECK)
The safety check condition during batch operation is set.
The safety check condition is selectable from [ON] or [OFF] for each of [SAFETY
CHECK 1] to [SAFETY CHECK 8] respectively.
Refer to Chapter
.
11 Weighing mode
Weight Controller CSD-918
Minebea Intec
EN-121
Содержание CSD-918 Series