OPERATION
37
Possible Cause
Horn
Monitor
Display
Guardian
Activated and
Engine Power
Reduced
Low Drive Lube
1.
2 Beeps‑1 Sec. Long
Yes
No
Electrical System Overload Protection
If an electrical overload occurs, a fuse or circuit breaker opens.
Locate and correct the problem before replacing the fuse or
resetting the circuit breaker.
A circuit breaker protects the engine wiring harness and
instrumentation power lead. Reset by pushing the reset button.
a
7764
a -
Reset button
In an emergency, if you cannot locate and correct the cause of the
high current draw, and you must operate the engine, perform the
following:
1. Turn off or disconnect all accessories connected to the engine
and instrumentation wiring and reset the circuit breaker.
2. If the breaker remains open, electrical overload is still
present. Inspect the electrical system.
1. This message refers to Transmission Fluid Overheat. Check the transmission
fluid level if this message is displayed.