6 - Adjustments
ExpressCard 2000 / ExpressCard 3000| Instant Issuance Card Personalization System | Hardware Service Manual
Page 337 of 356 (
D99875607-91
)
6.6.3
Calibrate the Embosser Wheel Home Position
To make sure the motor controller accurately centers the embosser wheel in the embosser bridge opening,
follow these steps:
1)
Close the ExpressCard top access door to make sure no light will interfere with the sensor.
2)
On the touchscreen, navigate to
Menu
>
Settings
>
Service
>
MCP Commands
to open the
Controller Commands
page.
3)
Press
Calibrate Wheel Home
button and wait for 10 seconds until the embosser stops moving. The
system will fill in a value below
Calibrate Wheel Home
.
4)
Repeat the
Calibrate Wheel Home
operation several times until you see the same number three
times in a row. If the number continues to change after 10 tests, report the unit’s failure to calibrate.
5)
Check that the value below
Calibrate Wheel Home
is
between 4 and 10
. If the value is not in that
range, report the unit’s failure to calibrate within the acceptable range.