Drive A1 Submenu
50
Parameter
[
Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Ana 1 Out
Offset
[A161]
(Digital to Analog #1 Output Offset) Offset
for scaling Analog Output Channel #1.
voltage
output
channel
analog
GAIN
OUT
ANA
OFFSET
OUT
ANA
creates
software
drive
signal
%
-99.9
– +99.9
0.0
Y
N
Ana 2 Out
Offset
[A162]
(Digital to Analog #2 Output Offset) Offset
for scaling Analog Output Channel #2.
voltage
output
channel
analog
GAIN
OUT
ANA
OFFSET
OUT
ANA
creates
software
drive
signal
%
-99.9
– +99.9
0.0
Y
N
Ana 1 Out
Gain
[A163]
(Digital to Analog #1 Output Gain) Adjusts
the scaling for the Analog Output Channel
#1.
NOTE: value of 1.0 = 0 to 10VDC signal.
voltage
output
channel
analog
GAIN
OUT
ANA
OFFSET
OUT
ANA
creates
software
drive
signal
none
0.0
– 10.0
1.0
Y
N
Ana 2 Out
Gain
[A164]
(Digital to Analog #2 Output Gain) Adjusts
the scaling for the Analog Output Channel
#2.
NOTE: value of 1.0 = 0 to 10VDC signal.
voltage
output
channel
analog
GAIN
OUT
ANA
OFFSET
OUT
ANA
creates
software
drive
signal
none
0.0
– 10.0
1.0
Y
N
Ser2 Insp
Spd
[A165]
(Serial Mode 2 Inspection Speed)
Used only with custom serial protocol (mode
2)
When in Serial Mode 2, this parameter
defines the inspection speed to be used. To
run in inspection speed via serial mode 2
requires that the run command for inspection
speed come from two sources, a command
sent in a serial message and via hardware
as a logic input defined as “SER2 INSP
ENA”.
ft/ min
0.0
– 100.0
30.0
-
Y
Y
m/sec 0.000
– 0.500
-
0.150
Ser2 Rs
Crp Spd
[A166]
(Serial Mode 2 Rescue Creep Speed)
Used only with custom serial protocol (mode
2)
When in Serial Mode 2 and SER2 FLT
MODE (C1)=rescue, this parameter defines
the creep speed that will be used in the
“rescue mode”.
ft/ min
0.0
– 300.0
10.0
-
Y
Y
m/sec 0.000
– 1.540
-
0.050
Ser2 Rs
Cpr Time
[A167]
(Serial Mode 2 Rescue Creep Time)
Used
only with custom serial protocol (mode 2)
When in Serial Mode 2 and SER2 FLT
MODE (C1)=rescue, this parameter defines
the maximum time the drive will continue to
run at rescue creep speed (defined by SER2
RS CRP SPD (A1) parameter) when
reacting to a serial fault. The time is defined
as the time running at creep speed. It does
not include the time it takes to decelerate to
creep speed.
sec
0.0
– 200.0
180.0
Y
Y
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......