Rx Com Status
000-0000-0000-0000
READY
RUN
USER
FAULT
TORQUE
LIMIT
SUB MENU
DATA ENTRY
Bit 0
Bit 15
Parameter
[Alphanumeric]
Description
Units
Hidden
item
Start Logic
i,ii
(continued)
Bit Name Description/Reason
8
SPD_REG_REL_BIT Bit is true when the speed regulator is
released.
9
SPD_REF_REL_BIT Bit is true when the speed regulator is
release if SPD REF RLS (C1) = SPD REG RLS, else, the
bit is true when the brake confirm has become active
10
BRAKE_PICK_BIT Bit is true when the speed regulator is
released and is used to open the mechanical brake
11
BRAKE_IS_PICKED_BIT Bit is true when brake confirm is
active
12
BRAKE_HOLD_BIT Bit is true when the brake pick
confirmation is received
13
LOW_GAIN_BIT Bit is true when the speed regulator is in
“low gain” mode
14
DOWN_BIT Bit is true when a down direction command has
been received
1=true
0=false
i,ii
N
i
,ii
Rx Com Status
i,ii
[D112]
(Serial Communications Status
i
,ii
)
Serial communication status display.
Bit Severity Name Description/Reason
0
Info
RX_INVALID_SETUP_ID; Invalid setup id on setup msg
1
Info
RX_SETUP_IN_RUN; A setup message to write was received
while the serial run bit was set.
2
Fatal
RX_TIMEOUT; A COMM FAULT was declared because of a
communication time-out.
3
Info /
Fatal
RX_INVALID_CHECKSUM; If COMM FAULT was declared
because of bad message checksums.
4
Info
RX_INVALID_MESSAGE; Invalid header character in
message.
5
Info
RX_FIFO_OVERRUN; Overflow has occurred.
6
Info
RX_INVALID_RUN_ID; Set if the Cmd_Id sent in the RUN
MESSAGE is not in range.
7
Info
RX_INVALID_MONITOR_ID (Not available in Mode 2) Set if
the Monitor_Id received in the run message is not in range.
8
Info
RX_INVALID_FAULT_ID; Set if the Fault_Id sent in the setup
message is not in range.
9
Info
RX_FAULT_DETECTED; COMM FAULT has been detected
10 Info
Fault_Mode_2 (Not available in Mode 1) Immediate Shutdown
Mode
11 Info
Fault_Mode_2_Run_Removal (Not available in Mode 1) Run
Removal Shutdown Mode
12 Info
Fault_Mode_2_Rescue (Not available in Mode 1) Rescue
Shutdown Mode
13 Info
Fault_Mode_3 (Not available in Mode 1 or 2) Immediate
Shutdown Fault
14
N/a
15 Fatal
RX_COMM_FAULT; COMM FAULT has been declared by the
drive
1=true,
0=false
i,ii
N
i
,ii
RX Error Count
[D113]
(Serial Communication Error Counter) - This function will monitor
invalid serial messages and increase the count per invalid
message. This is used as a diagnostic tool.
none
N
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......