Power Convert A4 Submenu
70
Parameter
[Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Id Dist Loop
Fc
iii
[A416]
(Corner Frequency on Distortion
Loop for Flux Current
iii
)
This parameter is the high-pass
corner frequency on the distortion
loop regulator for flux current. This
parameter is meant for advanced
operation; therefore, the parameter
will rarely need to be changed from
the default value.
sec
iii
0.1
– 30.0
iii
5.0
iii
Y
iii
N
iii
Iq Dist Loop
Fc
iiii
[A417]
(Corner Frequency on Distortion
Loop for Torque Current
iii
)
The parameter is the high-pass
corner frequency on the distortion
loop regulator for torque current.
This parameter is meant for
advanced operation; therefore, the
parameter will rarely need to be
changed from the default value.
sec
iii
0.1
– 30.0
iii
5.0
iii
Y
iii
N
iii
I Reg Cross
Freq
iii
[A418]
(Current Regulator Crossover
Frequency
iii
)
Transition frequency between
control at low frequency and higher
frequency. This parameter is meant
for advanced operation; therefore,
the parameter will rarely need to be
changed from the default value.
Units in percent of DC Stop Freq.
%
iii
0.0
– 300.0
iii
100.0
iii
Y
iii
N
iii
Dist Lp Off
Freq
iii
[A419]
(Distortion Loop Rolloff Frequency
iii
)
The frequency at which the
distortion loops begins to be phased
out. This parameter is meant for
advanced operation; therefore, the
parameter will rarely need to be
changed from the default value.
Hz
iii
0.0
– 99.9
iii
60.0
iii
Y
iii
N
iii
ILimit Integ
Gn
iii
[A420]
(Current Limit Integral Gain
iii
)
The Stall Prevention (Current Limit)
function’s integral gain. This
determines the response of the
function. Stall prevention causes
the drive to deviate from the
commanded speed to limit motor
current to a user set level. When
the motoring current limit is reached
(MTR TORQUE LIMIT(A1)), the stall
prevention function will reduce
speed. When the regenerating
current limit is reached (REGEN
TORQ LIMIT(A1)), the stall
prevention function will increase
speed in an effort to shed load. Stall
prevention can optionally be
disabled in regeneration by the Stall
Prevention Regen Enable (STALLP
REGEN ENA(C1)) parameter.
none
iii
0.00
– 9.99
iii
1.00
iii
N
iii
N
iii
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation
ii
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......