Quick Parameter Reference
2
Submenu Parameter
Units
Range
Default
Site
Setting
ENGLISH
(U3)
METRIC
(U3)
A1
Drive A1 Submenu
– For details, see Drive A1 Submenu on page 40.
A1
Contract Car Spd
fpm
0.0
– 1500.0
400.0
-
m/s
0.000
– 8.000
-
0.000
A1
Contract Mtr Spd
rpm
0.0
– 3000.0
1130.0
0.0
130.0
ii
Response
rad/sec
1.0
– 50.0
10.0
Inertia
sec
0.25
– 50.00
2.00
A1
Encoder Pulses
PPR
500
– 40000
Serial Cnts/Rev
none
0
– 25000
A1
Mtr Torque Limit
%
0.0
– 275.0
200.0
A1
Regen Torq Limit
%
0.0
– 275.0
200.0
Flux Wkn Factor
60
– 100
A1
Trq Lim Msg Dly
sec
0.00
– 10.00
0.50
2.00
Gain Reduce Mult
10
– 100
Gain Chng Level
0.0
– 100.0
100.0
Spd Dev Hi Level
0.0
– 99.9
10.0
Ramped Stop
Time
sec
0.00
– 2.50
0.20
0.50
A1
Contact Flt Time
Sec
0.10
– 5.00
0.50
A1
Contactor DO Dly
Sec
0.00
– 5.00
0.00
A1
Flt Reset Delay
Sec
0
– 120
5
A1
Flt Resets / Hour
#
0
– 10
3
A1
Brake Pick Time
Sec
0.00
– 5.00
1.00
Ab Zero Spd Lev
0.00
– 2.00
0.00
Ab Off Delay
sec
0.00
– 9.99
0.00
Brake Pick Delay
iii
sec
iii
0.00
– 5.00
iii
0.50
iii
A1
iii
Brake Drop Delay
iii
sec
iii
0.00
– 5.00
iii
0.50
iii
A1
Brake Hold Time
Sec
0.00
– 5.00
0.20
A1
iii
DC Start Level
iii
%
iii
0.0
– 150.0
iii
80.0
iii
50.0
iii
A1
iii
DC Stop Level
iii
%
iii
0.0
– 150.0
iii
50.0
iii
A1
iii
DC Stop Freq
iii
Hz
iii
0.0
– 10.0
iii
0.5
iii
A1
iii
DC Start Time
iii
sec
iii
0.00
– 5.00
iii
1.00
iii
A1
iii
DC Stop Time
iii
sec
iii
0.00
– 5.00
iii
1.00
iii
A1
i
,
ii
Overspeed Level
i,
ii
%
i,
ii
100.0
– 150.0
i,
ii
115.0
i,
ii
A1
i
,
ii
Overspeed Time
i,
ii
sec
i,
ii
0.00
– 3.00
i,
ii
1.00
i,
ii
A1
Overspeed Mult
%
100.0
– 150.0
125.0
A1
iii
Stalltest Level
iii
%
iii
0.0
– 200.0
iii
200.0
iii
A1
iii
Stall Fault Time
iii
sec
iii
0.00
– 9.99
iii
5.00
iii
A1
iii
Slip Comp Time
iii
sec
iii
0.01
– 2.00
iii
1.50
iii
A1
iii
Slip Comp Gain
iii
none
iii
0.00
– 2.00
iii
1.00
iii
A1
iii
Torq Boost Time
iii
sec
iii
0.01
– 1.00
iii
0.05
iii
A1
iii
Torq Boost Gain
iii
none
iii
0.00
– 2.00
iii
0.00
iii
A1
i
,
ii
Spd Dev Lo Level
i,
ii
%
i,
ii
0.1
– 20.0
i,
ii
10.0
i,
ii
20.0
i,
ii
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......