Drive A1 Submenu
40
Adjust A0 Menu
Drive A1 Submenu
NOTE: When
Hidden Item
appears with the
parameter description, it indicates that its
appearance in the list is controlled by the
HIDDEN ITEMS setting.
See details on page
NOTE: When
Run lock out
appears with the
parameter description, the parameter cannot
be changed when the drive is in the RUN
mode.
Parameter
[
Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Contract
Car Spd
[A101]
(Contract Car Speed) This parameter
programs the elevator contract speed in feet
per minute (fpm) or meters per second (m/s)
fpm
0.0
– 1500.0
400.0
-
N
Y
m/s
0.000
– 8.000
-
0.000
Contract
Mtr Spd
[A102]
(Contract Motor Speed) This parameter
programs the motor speed at elevator
contract speed in revolutions per minute
(rpm).
rpm
0.0
– 3000.0
1130.0
i,
iii
0.0
N
Y
130.0
ii
Response
i,
ii
[A103]
(Response
i,ii
) This parameter sets the
sensitivity of the drive’s speed regulator in
terms of the speed regulator bandwidth in
radians. The responsiveness of the drive as
it follows the speed reference will increase
as this number increases. If the number is
too large, the motor current and speed will
become jittery. If this number is too small,
the motor will become sluggish.
rad/
sec
i,ii
1.0
– 50.0
i,ii
10.0
i,ii
N
i,ii
N
i,ii
Inertia
i,ii
[A104]
(System Inertia
i,ii
) This parameter sets the
equivalent of the system inertia in terms of
the time it takes the elevator to accelerate to
motor base speed at rated torque.
sec
i,ii
0.25
– 50.00
i,ii
2.00
i,ii
N
i,ii
N
i,ii
Encoder
Pulses
[A105]
(Encoder Pulses) This parameter sets the
pulses per revolution the drive receives from
the encoder. This value is directly from the
encoder nameplate.
PPR
500
– 40000
1024
i,
iii
N
Y
10000
ii
Serial
Cnts/ Rev
ii
[A106]
(Serial Counts / Revolution
ii
) This parameter
sets the number of discrete absolute
positions per rotor revolution that the drive
receives from the absolute encoder (if
applicable). The value for a 13-bit encoder
is 8192. All recommended Heidenhain
encoders will be 8192.
none
ii
0
– 25000
ii
8192
ii
N
ii
Y
ii
Mtr Torque
Limit
[A107]
(Motoring Current Limit) This parameter sets
the maximum torque allowed when in the
motoring mode. This parameter may need
adjustment to reduce the effects of field
weakening. Units in percent of rated torque.
Note: The Torque Limit LED will be lit once
the limit defined by this parameter is
reached.
%
0.0
– 275.0
200.0
N
N
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......