User Switches C1 Submenu
81
Parameter
[Alphanumeric]
Description
Choices
Default
Hidden
item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Encoder
Select
ii
[C104]
(Encoder Selection
ii
)
HPV900 S2 PM drives can run either with
an incremental encoder or with an
Heidenhain Endat encoder. This
parameter sets the feedback option for the
drive.
incremental
ii
[1]
endat
ii
[2]
INCREMENTAL
ii
Y
ii
Y
ii
Encoder
Connect
i,ii
[C105]
(Encoder Connection
i,ii
)
This parameter allows the user to
electronically switch A and /A signals from
the encoder without moving any wiring.
NOTE: this parameter will be locked in
forward in PM if Encoder Select (C1) is
set to Endat.
forward
i,ii
[1]
reverse
i,ii
[2]
FORWARD
i,ii
Y
i,ii
Y
i,ii
Encoder
Fault
i,ii
[C106]
(Encoder Fault Enable
i
,ii
)
This parameter allows the user to
temporarily disable the Encoder Fault.
Adding this feature allows the user to
temporarily disable the Encoder Fault
during the initial start-up process, when
the motor model (defined by the A5 Motor
Parameters) is not clearly defined.
When the Encoder Fault is disabled
(ENCODER FAULT (C1) = disabled), the
drive will display the warning message
“EncoderFault OFF”, every time the RUN
command is removed.
IMPORTANT: After the motor parameters
in A5 have been established, the Encoder
Fault should be enabled (ENCODER
FAULT (C1) = enabled).
enable
i
,ii
[1]
disable
i
,ii
[0]
ENABLE
i,ii
Y
i
,ii
Y
i
,ii
Cont Confirm
Src
[C107]
(Contactor Confirm Source)
This switch selects if hardware
confirmation of motor contactor closure is
necessary before drive attempts to pass
current through motor. If hardware
confirmation is available set to
EXTERNAL TB and select the Contact
Cnfirm signal on a logic input terminal.
none
[0]
external tb
[1]
NONE
EXTER-
NAL TB
Y
Y
Fast Flux
i
[C108]
(Fast Flux Enable
i
)
This parameter addresses the method the
HPV 900 Series 2 uses to build up flux in
the motor. Enabling the Fast Flux function
can decrease the motor fluxing time
significantly. By decreasing the motor’s
flux time, the starting takeoff time will also
be decreased. For more information, see
Fast Flux on page 93.
enable
i
,ii
[1]
disable
i
,ii
[0]
DISABLE
i
Y
i
Y
i
HI/LO Gain
Src
i
,ii
[C109]
(High / Low Gain Source
i
,ii
)
High / low gain change switch source. For
more information, see HI/LO GAIN SRC
on page 93.
internal
i
[1]
external tb
i
,ii
[2]
serial
i
,ii,ii
[3]
INTERNAL
i,ii
Y
i
,ii
Y
i
,ii
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......