Drive A1 Submenu
46
Parameter
[
Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Torq Boost
Time
iii
[A137]
(Torque Boost Time Constant
iii
) This
parameter is the torque boost filter time
constant. Adjusted for torque compensation
response and stability. Increasing the value
of the parameter, decreases response.
Reducing the parameter to a lower value
increases response.
NOTE: it is usually best to leave this
parameter set at the default of 0.5 seconds.
Torque compensation automatically boosts
the drive’s output voltage, in excess of the
programmed V/Hz pattern, as the load
demand increases. Torque compensation
counters the voltage drop in the motor stator
resistance. This function has the greatest
effect at low speeds improving load
response. When using torque compensation,
a valid value must be entered for the motor’s
no-load current (% NO LOAD CURR(A5))
sec
iii
0.01
– 1.00
iii
0.05
iii
N
iii
N
iii
Torq Boost
Gain
iii
[A138]
(Torque Boost Gain
iii
) This gain controls the
differential term in the voltage boost
function. This affects the rate of response of
the torque boost. Setting the Torque Boost
Gain to 0.00 disables the torque boost
function.
NOTE: this function is defaulted off (TORQ
BOOSTGAIN=0.0). If adjustments need to
be made follow the guidelines listed in the
“Performance Adjustments” on page181.
Torque compensation automatically boosts
the drive’s output voltage, in excess of the
programmed V/Hz pattern, as the load
demand increases. Torque compensation
counters the voltage drop in the motor stator
resistance. This function has the greatest
effect at low speeds improving load
response. When using torque compensation,
a valid value must be entered for the motor’s
no-load current (% NO LOAD CURR(A5))
none
iii
0.00
– 2.00
iii
0.00
iii
N
iii
N
iii
Spd Dev
Lo Level
i,ii
[A139]
(Speed Deviation Lo Level
i
,ii
) Range around
the speed reference for speed deviation low
logic output. For more information, see SPD
DEVIATION on page 56. Units in percent of
contract speed.
%
i,ii
0.1
– 20.0
i,ii
10.0
i,ii
20.0
i,ii
Y
i
,ii
N
i
,ii
Spd Dev
Time
i,ii
[A140]
(Speed Deviation Time
i
,ii
) This parameter
defines the time the speed feedback needs
to be in the range around the speed
reference defined by SPD DEV LO LEVEL
(A1) before the Speed Deviation Low logic
output is true. For more information, see
SPD DEVIATION on page 56.
sec
i,ii
0.00
– 9.99
i,ii
0.50
i,ii
5.00
i,ii
Y
i
,ii
N
i
,ii
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......