Quick Parameter Reference
13
Sub
menu
Parameter
Units
D1
Elevator Data D1 Submenu
D1
Speed Command
ft/min or m/s
D1
Speed Reference
ft/min or m/s
D1
Speed Feedback
ft/min or m/s
D1
Analog Spd Cmd
volts
D1
Encoder Speed
rpm
D1
i
,
ii
Speed Error
i,
ii
ft/min or m/s
i,
ii
D1
i
,
ii
Est Inertia
i,
ii
seconds
i,
ii
D1
Logic Outputs
1 = true; 0 = false
D1
Logic Inputs
1 = true; 0 = false
D1
Rx Logic In
1 = true; 0 = false
D1
i
,
ii
Start Logic
i,
ii
1 = true; 0 = false
i,
ii
D1
i
,
ii
Rx Com Status
i,
ii
1 = true; 0 = false
i,
ii
D1
Rx Error Count
none
D1
i
,
ii
Pre-Torque Ref
i,
ii
% of rated torque
i,
ii
D1
i
,
ii
Spd Reg Torq Cmd
i,
ii
% of rated torque
i,
ii
D1
i
,
ii
Tach Rate Cmd
i,
ii
% of rated torque
i,
ii
D1
i
,
ii
FF Torque Cmd
i,
ii
% of rated torque
i,
ii
D1
Enc Position
None
D1
Enc Revolutions
None
D1
DCP Command
1 = true; 0 = false
D1
DCP Status
1 = true; 0 = false
D1
Measured PPR
PPR
D1
Endat Abs Fdbk
ii
None
D1
Z Edge Count
ii
None
D1
NTSD 1 Spd Fdbk
ft/min or m/s
D1
NTSD 2 Spd Fdbk
ft/min or m/s
D1
NTSD 3 Spd Fdbk
ft/min or m/s
D2
Power Data D2 Submenu
D2
DC Bus Voltage
Volts
D2
Motor Current
Amps
D2
Motor Voltage
Volts
D2
Motor Frequency
Hz
D2
Motor Torque
% rated torque
D2
i
Est No Load Curr %
i
%
i
D2
i
Est Rated RPM
i
Rpm
i
D2
i
,
ii
Torque Reference
i,
ii
% of rated torque
i,
ii
D2
i
Flux Reference
i
%
i
D2
i
Flux Output
i
%
i
D2
% Motor Current
% rated current
D2
Power Output
kW
D2
ii
D-Curr Reference
ii
%
ii
D2
i,
iii
Slip Frequency
i,
iii
Hz
i,
iii
i
Parameter accessible through
CLOSED LOOP (U9)
ii
Parameter accessible through
PM (U9)
Sub
menu
Parameter
Units
D2
Motor Overload
%
D2
Drive Overload
%
D2
Flux Current
%
D2
Torque Current
% rated current
D2
Flux Voltage
% rated volts
D2
Torque Voltage
% rated volts
D2
Base Impedance
Ohms
D2
ii
Rated Excit Freq
ii
Hz
ii
D2
ii
Rotor Position
ii
none
ii
D2
Drive Temp
Deg C
D2
Highest Temp
Deg C
U1
Password U1 Submenu
U1
Enter password
U1
New password
U1
Password lockout
U2
Hidden Items U2 Submenu
U2
Hidden Items Enable
U3
Units U3 Submenu
U3
Units Selection
U4
Ovrspeed Test U4 Submenu
U4
Overspeed Test
U5
Restore Dflts U5 Submenu
U5
Rst Mtr Dflts
U5
Rst Drive Dflts
U6
Drive Info U6 Submenu
U6
Drive Version
U6
Boot Version
U6
Cube ID
U6
Drive Type
U7
Hex Monitor U7 Submenu
U7
Probe Addr1
U7
Probe Ctrl 1
U7
Probe Addr 2
U7
Probe Ctrl 2
U7
Probe Addr 3
U7
Probe Ctrl 3
U7
Probe Addr 4
U7
Probe Ctrl 4
U7
Cycle Sim
U7
Debug Enable
U8
Language Sel U8 Submenu
U8
Language Select
U9
Basics U9 Submenu
U9
Drive Mode
iii
Parameter accessible through
OPEN LOOP(U9)
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......