Drive A1 Submenu
55
GAIN CHNG LEVEL
i,ii
(Gain Change Level)
Note: This parameter is only accessible and
usable when the drive is set for Closed Loop
Operation.
When the gain control is set to internal, the
drive will control the high/low gain switch. This
parameter sets the speed reference level,
when the drive is in ‘low gain’ mode.
The speed regulator high / low gain function
was developed in response to high
performance elevator requirements where the
resonant nature of the elevator system
interferes with the speed response of the drive.
When the speed response (gain) is set to high
levels, the resonant characteristics created by
the spring action of the elevator ropes can
cause car vibration. To solve this problem, the
speed regulator is set to a low enough
response (gain) so that the resonant
characteristics of the ropes are not excited.
This is accomplished by controlling the
sensitivity or response of the speed regulator
via the high / low gain switch and gain reduce
multiplier.
By using the gain reduce multiplier; the user
can specify a lower response (gain) for the
speed regulator when the drive is at higher
speeds. The gain reduce multiplier (GAIN
REDUCE MULT(A1)) tells the software how
much lower, as a percentage, the speed
regulator response (gain) should be.
The high / low gain switch determines when
the HPV 900 Series 2 is in ‘low gain’ mode. In
the ‘low gain’ mode, the gain reduce multiplier
has an effect on the speed regulator’s
response (gain).
The drive allows for the high / low gain switch
to be controlled either externally or internally.
The high / low gain source parameter (HI/LO
GAIN SRC(C1)) allows for this external or
internal selection.
The high / low gain switch can be controlled
externally by either:
a logic input
the serial channel
The high / low gain switch can also be
controlled internal by:
i
Parameter accessible through
CLOSED LOOP (U9)
ii
Parameter accessibly through
PM (U9)
the gain change level parameter (GAIN
CHNG LEVEL(A1)), which defines a
percentage of contract speed
With the drive set to internal control, the speed
regulator will go into ‘low gain’ mode when the
drive senses the motor is above a defined
speed level. The defined speed level is
determined by the gain change level
parameter.
An example of internal high / low gain control
is shown below.
High / Low Gain Example
iii
Parameter accessible through
OPEN LOOP(U9)
HPV 900 Series 2 Parameter
Settings
HI/LO GAIN SRC = internal
GAIN REDUCE MULT = 80%
GAIN CHNG LEVEL = 10 %
RESPONSE = 10.0 rad/sec
Response of
Speed Regulator
10.0 rad/sec
0%
contract
speed
low gain
mode
Response of
Speed
Regulator
8.0 rad/sec
10%
contract
speed
Response of
Speed Regulator
10.0 rad/sec
0%
contract
speed
speed
reference
100%
contract
speed
10%
contract
speed
Response of
Speed Regulator
8.0 rad/sec
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......