Appendix
– Testpoints
166
Appendix
Testpoints (EnDat Option Card part number 46S04327-1030 through 46S04327-1010 - Other)
Figure 41: EnDat Option Card Other Testpoints
TP13
Analog Common
TP15
Analog Common
TP20
Common
TP23
Common
TP3
EnDir
TP4
EDataO
TP5
EClk
TP9
A_D_M
TP11
B_D_M
TP1
AEnc
TP2
BEnc
TP12
AOut1
TP14
AOut2
JM2
**
Power Sense Enable
JM1
*
Clock
Adjustment
*For encoder cables longer than 15m/50ft, JM1 should be set to position 2-3 to slow down
the serial clock. For shorter cable lengths, JM1 should stay in position 1-2.
** For encoder cables longer than 15m/50ft, it is recommended to connect the
–SENSE and
+SENSE lines into the terminal block and JM2 set to position 2-3. The drive will automatically
produce proper voltage on the encoder if JM2 is set to position 2-3. If JM2 is set to position 1-
2, the remote power sense is disabled and the sense wires do not need to be connected. The
maximum cable length is 100m (328ft).
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......