User Switches C1 Submenu
92
Parameter
[Alphanumeric]
Description
Choices
Default
Hidden
item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Fan PWM
Enable
[C152]
This parameter allows the user to enable
and disable soft starting on the fans.
Enable
[1]
Disable
[0]
Enable
N
Y
PPT Select
[C153]
(Pulse Pre-Torque) Enables the PPT
feature. PPT is designed for use with
certain brake types to eliminate the bump
felt and heard as the brake is released at
the start of travel.
Enable
[1]
Disable
[0]
Disable
N
Y
Table 15: User Switches C1 Submenu