User Switches C1 Submenu
84
Parameter
[Alphanumeric]
Description
Choices
Default
Hidden
item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Auto Stop
[C120]
(Auto Stop Function Enable)
The Auto Stop function determines how
the drive logic will respond to a zero or
non-zero speed command. If Speed
Command SRC (C1) is set to Analog,
then SPD ZERO BND (A1) must be non
zero. For more information, see Auto
Stop on page 96.
enable
[1]
disable
[0]
DISABLE
Y
Y
Stall Test
Ena
iii
[C121]
(Stall Test Enable
iii
)
When enabled, the function checks that
motor current goes at or above a
percentage (defined by STALL TEST
LVL(A1)) for defined amount of time
(defined by STALL FAULT TIME(A1)). If
the motor current exceeds the defined
parameters a STALL TEST FAULT will be
declared.
enable
iii
[1]
disable
iii
[0]
ENABLE
iii
N
iii
Y
iii
Stall Prev
Ena
iii
[C122]
(Regeneration Stall Prevention Enable
iii
)
When enabled, the Stall Prevention
(Current Limit) function is enabled during
regeneration. When the defined
regeneration current limit is reached
(REGEN TORQ LIMIT(A1)), the stall
prevention function will increase speed in
an effort to shed load. Also, the
responsiveness of the stall prevention
function is determined by the Current Limit
Integral Gain (ILIMT INTEG GAIN(A4))
parameter.
enable
iii
[1]
disable
iii
[0]
DISABLE
iii
N
iii
Y
iii
Serial Mode
[C123]
(Serial Mode Selection)
This parameter selects between serial
protocols. The choices are:
Mode 1
– selects the Magnetek
standard protocol.
Mode 2
– selects a Magnetek
alternative protocol.
Mode 2 Test
– test mode used when
testing custom protocol serial mode 2.
Mode 3 - selects a Magnetek
alternative protocol.
DCP3
– Drive Control Position
Protocol 3 .
DCP4
– Drive Control Position
Protocol 4
None
[0]
mode 1
[1]
mode 2
[2]
mode 3
[3]
DCP4
[4]
DCP3
[5]
mode 2 test
[6]
NONE
Y
Y
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......