Problem Possible
causes
Remedies
Power is not supplied to
transmitter after
power-on.
• No voltage supplied.
• Check battery for contact failure
due to damage or dirt.
• Set charged battery into battery
compartment.
• Fully charge the battery.
Low voltage alarm goes
off immediately after
start of operation.
• Battery contact failure due
to damage or dirt.
• Battery is not charged.
• Battery has failed.
• Check battery for contact failure
due to damage or dirt.
• Fully charge battery.
• Check if battery charging process
is correct.
• Check if transmitter functions
correctly by using spare battery or
fully charged battery.
Transmitter display
illuminates but any
control commands
cannot be performed.
• Voltage is not applied to
receiver.
• Failure in connection for
wireless communication.
• Check receiver cable for
disconnection.
• Check functionality with LED in
receiver control light field.
Individual commands
cannot be executed.
• Receiver has failed.
• Connection to machine is
interrupted.
• Check connection cable to
receiver for disconnection.
If the problem is not solved after applying the suggested remedies above, contact us or our sal
es service agent or HBC-radiomatic GmbH.
Symptom Causes
Remedies
No response from
transmitter even after it
is powered on.
• The power is not supplied. • Check the battery terminal for
damage or dirt.
• Install charged battery.
• Fully recharge the battery.
Voltage drop alarm goes
off immediately after
power-on.
• Scratch or dirt on battery
terminal.
• Battery has not been
charged.
• Battery failure
• Check the battery terminal for
damage or dirt.
• Fully recharge the battery.
• Check if the battery is charged
properly.
• Check transmitter functionality by
using fully charged spare battery.
Some commands cannot
be executed.
• Receiver failure
• Wiring to transmitter is
disconnected.
• Check receiver for wiring.
If the above measures do not solve the problem, contact us, our sales service agent or
HBC-radiomatic GmbH.
Содержание MC815C
Страница 2: ......
Страница 30: ...20 This Page Intentionally Left Blank...
Страница 73: ...63 3 Total load chart 106 2186300...
Страница 75: ...65 9 Precautions when using 106 2186600...
Страница 76: ...66...
Страница 82: ...72 This Page Intentionally Left Blank...
Страница 197: ...187 Remote control menu...
Страница 254: ...244 This Page Intentionally Left Blank...
Страница 314: ...304...
Страница 338: ...328 This Page Intentionally Left Blank...
Страница 343: ...333 2 SPECIFICATION DIMENSIONAL DRAWING...
Страница 344: ...334 3 DIMENSIONAL DRAWING OF OUTRIGGER WIDTH...
Страница 357: ...347 5 WORKING RADIUS LIFTING HEIGHT...
Страница 362: ...352 1 Diagram of fly jib working range chart 106 2189200...
Страница 397: ...387 9 4 WORKING RADIUS LIFTING HEIGHT...
Страница 398: ...388 This Page Intentionally Left Blank...
Страница 402: ...392 1 Searcher hook working range diagram 106 2189200...
Страница 403: ...393 6 Maximum rated total load 106 4716100 2 locations 7 Notice on pin holes CL000100001 2 locations...
Страница 424: ...414 9 4 WORKING RADIUS LIFTING HEIGHT...
Страница 426: ......