16
Id.-Nr.: 1556.212 .1-07
System overview
Available MO CM variants
Processor
Safety func-
tion
Master in-
terface
Slave inter-
face
Safety con-
trol
MO
CM-3.x-..-00x
x
Intel Atom
E660 1,3 GHz
-
1 x EtherCAT
master inter-
face
RT-Ethernet
Slave
-
MO
CM-3.x-..-01x
x
Intel Atom
E3845 1,9
GHz
-
1 x EtherCAT
master inter-
face
RT-Ethernet
Slave
-
MO
CM-6.x-..-00x
x
Intel i3 Dual-
Core 2310E
2,1 GHz
-
2 x EtherCAT
master inter-
face
RT-Ethernet
Slave
-
MO
CM-6.x-..-01x
x
Intel Celeron
3955U 2,0
GHz
-
1 x EtherCAT
master inter-
face
RT-Ethernet
Slave
-
Drive modules
Designation
EtherCAT (CoE)
CAN (CANOpen)
SO CM-x
x
-
ServoOne 84
x
-
ServoOne 22 Junior
x
-
ServoOne Safety
x
-
CDB2000, CDB3000
-
x
CDE3000
-
x
CDF3000, CDF3000Light
-
x
ServoCPlus
-
x
ServoA
x
-
Supply modules
Supply module
CAN
EtherCAT
SO CMP
-
x
Information
The order numbers and details concerning the devices can be found in the
respective operation manual
3.7
Buses
The following sections give an overview and description about all buses supported by
MotionOne system.
The following master field bus interfaces are available depending on the control:
•
EtherCAT
•
Profinet
•
CAN
•
Ethernet
The following slave field bus interfaces are available depending on the control:
•
EtherCAT
•
Profinet
•
Ethernet/IP
•
CAN
3.7.1
EtherCAT
All variants of the CPU module can be can be equipped with an EtherCAT interface
via software configuration. EtherCAT interfaces can be used for the connection of
slave devices (e.g. drives, I/O modules).
CPU module
Onboard
LANX 252/A
LACP 265/X
1x
1x
Information
The interfaces of the option modules as well as the ETH2 port of the con-
trol can only be used as EtherCAT interface. A use as Ethernet is not pos-
sible.