47
Id.-Nr.: 1556.212.1-07
Technical data
15
Technical data
Detailed information concerning the technical data can be found in the respective
project engineering manuals.
15.1
Ambient conditions
Operating temperature:
+5 °C to +55 °C
Average temperature over 24 hours:
Open devices: 50 °C
Storage temperature:
-40 °C to +70 °C (except displays)
Relative humidity of air:
10% to 95% (non-condensing)
Vibration resistance:
3.5 mm amplitude for 5 ≤ f < 9 Hz and 1.0 g
for 9 ≤ f < 150 Hz
Shock resistance:
max. 15 g, 11 ms (half sinus)
Contamination level:
2, non-conductive contamination, when moist
briefly conductive
Sea level:
• Operation:
max. 2000 m
• Storage:
max. 3000 m