17
Id.-Nr.: 1556.212.1-07
System overview
3.7.2
Profinet
All variants of the MO CM CPU modules can be equipped with an (Slave) PROFINET
interface via software configuration. A CPU module can thus be connected to a (su-
perior) Profinet controller. PROFINET (Process Field Network) is an open Ethernet
standard for automation based on Industrial Ethernet. Industrial Ethernet and Stan-
dard Ethernet components can be used together. PROFINET enables the automation
of applications with real-time requirement as well as a seamless integration of field-
bus systems.
3.7.3
EtherNet/IP
EtherNet/IP (Ethernet Industrial Protocol) is an open commercial fieldbus system,
which is standardized in the international standard series EN 61158. EtherNet/IP
uses the industrial protocol CIP (Common Industrial Protocol) via the classic Ethernet
network.
All variants of the MO CM CPU modules can be equipped with an (Slave) EtherNet/
IP interface via software configuration.
3.7.4
CAN
The availability of CAN interfaces in the system is realized by the onboard interface
of the LACP 26x or by adding a LAFM 200/A or FM 500 on this CPU module or on a
bus link module.
3.7.5
Ethernet
All versions of the CPU modules are equipped onboard with two Ethernet interfaces.
The ETH0 interface is used as a connection to the external network, ETH1 is exclu-
sively used for the connection of the machine network.
3.8
VisuOne - Visualization components
VisuOne provides a large selection of stationary panels and mobile handheld termi-
nals. Visualization masks can easily be created and configured by using ViEditor. A
large number of widgets and predefined system masks are available for application
development.
The following sections give an overview about visualization components supported
by the MotionOne 3 system.
3.8.1
Stationary Visualization
The following table contains a list of available panels for stationary visualization. All
panels are equipped with touch screens.
Panel
Description
LAOP 430-LD/A-0000 8,4" TFT, 800x600 pixel, 10 keys with LED, 16 digital inputs
LAOP 450-LD/A-0000 12,1" TFT, 800x600 pixel, 10 keys with LED, 16 digital inputs
LAOP 460-LD/A-0000 15" TFT, 1024x768 pixel, 10 keys with LED, 16 digital inputs
3.8.2
Visualization systems
With the visualization systems a visualization application for mobile handheld termi-
nals or stationary panels can be created with ViEditor.
The following tables contains a list of available visualization systems.
KeView
Description
ViApp
The visualization system is optimized for touch operating and
provides beside basic functionalities such as online help, print,
unit and language switching additional functionalities for diag-
nosis, service and system optimization.
3.9
MotionCenter Toolsuite
The tools connect to the controller via Ethernet. They are used for configuration,
parametrization, programing, debugging and diagnosis of a control. The following
tools are available:
•
MotionCenter
for configuration and programming::
MotionCenter is used for configuration, parameterization, programming and de-
bugging of control applications. The configuration of a robot is carried out via
configuration masks.
•
ViEditor
for programming visualizations::
ViEditor is used for programming ViApp and TeachView visualizations which can
be displayed on stationary panels or on mobile handheld terminals.
•
Configuration, parameterization and diagnosis with
DriveManager
: