67
Id.-Nr.: 1556.212.1-07
Appendix: Connection examples
20
Appendix: Connection examples
This chapter describes possible connection examples of a MO CM with a SO CMP
and the axis modules SO CM-x.
The supply of the axis controller takes place via the 400 V DC-link circuit of the sup-
ply unit. The MO CM control must always be supplied with 24V (control voltage). The
24 V can be supplied either via an optional internal power supply unit of the SO CMP
supply unit or via an external power supply unit. The optional internal power supply
unit of the supply unit is operated separately with 400 V; a second 400 V connection
must be provided on the SO CMP supply unit.
20.1
MO CM with connected axis group
Connection example of the supply unit with axis controller directly added to the MO
CM control. Typical structure on a single axis machine or dual axis system.
Supply unit with optional power unit
1
DC-link circuit
2
Power cable
3
Transmitter cable
Supply unit without optional power unit
1
DC-link circuit
2
Power cable
3
Transmitter cable
20.2
MO CM with directly added SO CMP
with power unit and separate SO CMP
without power unit
Connection example of the supply unit with optional power unit with axis modules di-
rectly added to the MO CM and a separate additional supply module without optional
power unit with added axis controllers.