68
Id.-Nr.: 1556.212 .1-07
Appendix: Connection examples
1
DC-link circuit
2
Power cable
3
Transmitter cable
20.3
MO CM with directly added SO CMP
with power unit and separate SO CMP
with power unit
Connection example of the supply unit with optional power unit with axis controller di-
rectly added to the MO CM and a separate additional supply unit also with optional
power unit with added axis contollers
Information
Only one SO CMP must provide the 24 V supply. It must therefore be en-
sured that the 24 V circuits are separated from each other when multiple
SO CMP with power unit are utilized in the system.
1
DC-link circuit
2
Power cable
3
Transmitter cable
If the supply units are installed directly next to each other due to space constraints, it
must be ensured that the supplies (the 24 V as well as the 400 V bars) are not con-
nected with the additional supply units.
1
DC-link circuit
2
Power cable
3
Transmitter cable