Surface inspection locations
This figure shows the areas to inspect for wear on the bearing frame outside surface.
228
Figure 20: Outside surface inspection locations
This figure shows the areas to inspect for wear on the bearing frame inside surface.
241
Figure 21: Inside surface inspection locations
C-face adapter inspection
Checklist
• Visually inspect the C-face adapter (340) for cracks.
• Check all surfaces for rust, scale, or debris and remove all loose and foreign material.
• Check for corrosion or pitting.
This figure shows the areas to inspect for cracks on the C-face adapter.
Figure 22: C-face adapter inspection locations