Assemble the rotating element and the bearing frame ( XLT-i and i17 with
duplex bearings)
CAUTION:
• Wear insulated gloves when you use a bearing heater. Bearings get hot and can cause physical injury.
• Use care when you handle the shaft because it can be heavy. Failure to do so could result in personal
injury.
NOTICE: Make sure that the pipe threads are clean, and that you apply thread sealant to the plugs and
fittings. Failure to do so may result in equipment damage or decreased performance.
NOTICE: Use an induction heater that heats as well as demagnetizes the bearings when you install
bearings. Failure to do so may result in decreased performance.
1. Prepare the bearing frame (228) as follows (see the illustration):
a) Install the oil-fill plug (113A).
b) Install the oil-drain plug (408A).
c) Install the sight glass (319).
d) Install the sight oiler plug (408J).
e) Install the plug for the oil-cooler inlet (408L).
f) Install the plug for the oil-cooler outlet (408M).
g) Install four oil-mist connection plugs (408H).
Or: Install two grease fittings (193) and two grease-relief plugs (113).
370F
241
408A
408L
319
228A
113A
408N
408M
2. Install the outboard bearings (112A) on the shaft (122).
The regreasable bearing has a single shield. Make sure that the bearing is installed with the shield away
from the impeller.
The duplex bearings are mounted back-to-back. Make sure that the orientation of the bearings are
correct.
a) Inspect the shaft (122) to ensure that it is clean, dimensionally correct, and is free of nicks and
burrs.
Maintenance
102
Model HT 3196 i-FRAME Installation, Operation, and Maintenance Manual
Содержание HT 3196 i-FRAME
Страница 1: ...Goulds Pumps Installation Operation and Maintenance Manual Model HT 3196 i FRAME ...
Страница 2: ......
Страница 140: ...Certification CE or CE ATEX 138 Model HT 3196 i FRAME Installation Operation and Maintenance Manual ...
Страница 141: ...ATEX notification Certification CE or CE ATEX Model HT 3196 i FRAME Installation Operation and Maintenance Manual 139 ...
Страница 143: ...Certification CE or CE ATEX Model HT 3196 i FRAME Installation Operation and Maintenance Manual 141 ...
Страница 147: ......