Part description HT 3196
3196
3796
HT 3196
CV 3196
LF 3196
3198
NM 3196
Casing
Impeller
Cover
Power end
Figure 6: HT 3196 part description
This table describes the pump casing parts.
Table 3: Casing
Part
Description
Discharge
Top-centerline
Casing ventilation
Self venting
Mounting method
Centerline-mounted to withstand misalignment and distortion from thermal piping
loads. It also maintains vertical alignment at elevated temperatures.
Standard flange
ANSI class 300 raised-face serrated flange.
Impeller
The impeller is
• fully open
• screwed onto the shaft
The threads are sealed from the pumped liquid by a graphite O-ring.
Product Description
Model HT 3196 i-FRAME Installation, Operation, and Maintenance Manual