1
2
3
4
1.
Annular groove
2.
Pump-side end plate
3.
Driver
4.
Pump half of the coupling guard
The annular groove in the coupling guard half must fit around the end plate.
1
2
3
1.
Annular groove
2.
End plate (pump end)
3.
Guard half
4. Use a bolt, a nut, and two washers to secure the coupling guard half to the end plate. Tighten securely.
1
2
3
1.
Nut
2.
Washer
3.
Bolt
5. Put the driver half of the coupling guard in place:
a) Slightly spread the bottom apart.
Commissioning, Startup, Operation, and Shutdown
48
Model HT 3196 i-FRAME Installation, Operation, and Maintenance Manual
Содержание HT 3196 i-FRAME