113A
319
Oil lubricated
bearings
Correct
level
3. Replace the fill plug.
Lubricate the bearings with pure oil mist
Oil mist is an optional feature for this pump.
• To lubricate bearings with pure oil mist, follow the instructions provided by the manufacturer of the
oil-mist generator.
The inlet connections are on the top of the bearing frame.
Greased-for-life bearing lubrication
The bearing manufacturer fills greased-for-life bearings with grease and seals them at the factory. You do
not need to lubricate or seal these bearings. Refer to the Maintenance chapter for re-greasing and
maintenance procedures for these bearings.
Shaft-sealing options
In most cases, the manufacturer seals the shaft before shipping the pump. If your pump does not have a
sealed shaft, see the Shaft-seal maintenance section in the Maintenance chapter.
This model uses these types of shaft seals:
• Cartridge mechanical seal
• Conventional inside-component mechanical seal
• Conventional outside-component mechanical seal
• Packed-stuffing-box option
Mechanical seal options
Pumps are usually shipped with mechanical seals installed. If they are not, then refer to the mechanical seal
manufacturer's installation instructions.
These are the mechanical seal options for this pump:
• Cartridge mechanical seal
• Conventional inside component mechanical seal
• Conventional outside component mechanical seal
Connection of sealing liquid for mechanical seals
Seal lubrication is required
Seal faces must have liquid film between them for proper lubrication. Locate the taps using the illustrations
shipped with the seal.
Seal flushing methods
You can use these methods in order to flush or cool the seal:
Commissioning, Startup, Operation, and Shutdown
52
Model HT 3196 i-FRAME Installation, Operation, and Maintenance Manual
Содержание HT 3196 i-FRAME
Страница 1: ...Goulds Pumps Installation Operation and Maintenance Manual Model HT 3196 i FRAME ...
Страница 2: ......
Страница 140: ...Certification CE or CE ATEX 138 Model HT 3196 i FRAME Installation Operation and Maintenance Manual ...
Страница 141: ...ATEX notification Certification CE or CE ATEX Model HT 3196 i FRAME Installation Operation and Maintenance Manual 139 ...
Страница 143: ...Certification CE or CE ATEX Model HT 3196 i FRAME Installation Operation and Maintenance Manual 141 ...
Страница 147: ......