Remove the stuffing-box cover (3196, CV 3196, HT 3196, LF 3196, 3796)
1. Remove the gland nuts (355) and the gland (107).
2. Remove the stuffing-box-cover nuts (370H).
3. Remove the stuffing-box cover (184).
107
184
370H
355
184
370H
355
107
4. Remove the shaft sleeve (126).
105
184
106
5. Remove the packing (106) and lantern ring (105) from the stuffing-box cover (184).
A lantern ring does not come with self-lubricating graphite packing.