Reference drawing
The manufacturer supplies a reference drawing with the data package. Keep this drawing for future use
when you perform maintenance and seal adjustments. The seal drawing specifies the required flush fluid
and attachment points.
Before you start the pump
Check the seal and all flush piping.
Mechanical seal life
The life of a mechanical seal depends on the cleanliness of the pumped fluid. Due to the diversity of
operating conditions, it is not possible to give definite indications as to the life of a mechanical seal.
Packed stuffing-box maintenance
WARNING:
• Packed stuffing boxes are not allowed in an ATEX-classified environment.
• Never attempt to replace the packing until the driver is properly locked out and the coupling spacer is
removed.
Accepted leakage rate
It is not necessary to shut down or disassemble the pump to inspect the packing operation. During normal
operation, the packing should leak approximately one drop per second.
Adjustment of gland
Adjust the gland if the leakage rate is greater than or less than the specified rate.
Evenly adjust each of the two gland bolts with a one-quarter (1/4) turn until the desired leakage rate is
obtained. Tighten the bolts to decrease the rate. Loosen the bolts to increase the rate.
Tightening of packing
NOTICE: Never over-tighten packing to the point where less than one drop per second is observed.
Over-tightening can cause excessive wear and power consumption during operation.
If you cannot tighten the packing to obtain less than the specified leakage rate, then replace the packing.
Disassembly
Disassembly precautions
WARNING:
• This manual clearly identifies accepted methods for disassembling units. These methods must be
adhered to. Trapped liquid can rapidly expand and result in a violent explosion and injury. Never apply
heat to impellers, propellers, or their retaining devices to aid in their removal.
• Make sure that the pump is isolated from the system and that pressure is relieved before you
disassemble the pump, remove plugs, open vent or drain valves, or disconnect the piping.
• Always disconnect and lock out power to the driver before you perform any installation or
maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical
injury.
• Crush hazard. The unit and the components can be heavy. Use proper lifting methods and wear steel-
toed shoes at all times.
• The pump can handle hazardous and toxic fluids. Identify the contents of the pump and observe
proper decontamination procedures in order to eliminate the possible exposure to any hazardous or
toxic fluids. Wear the proper personal protective equipment. Potential hazards include, but are not
limited to, high temperature, flammable, acidic, caustic, explosive, and other risks. You must handle
and dispose of pumped fluid in compliance with the applicable environmental regulations.
Maintenance
64
Model HT 3196 i-FRAME Installation, Operation, and Maintenance Manual
Содержание HT 3196 i-FRAME
Страница 1: ...Goulds Pumps Installation Operation and Maintenance Manual Model HT 3196 i FRAME ...
Страница 2: ......
Страница 140: ...Certification CE or CE ATEX 138 Model HT 3196 i FRAME Installation Operation and Maintenance Manual ...
Страница 141: ...ATEX notification Certification CE or CE ATEX Model HT 3196 i FRAME Installation Operation and Maintenance Manual 139 ...
Страница 143: ...Certification CE or CE ATEX Model HT 3196 i FRAME Installation Operation and Maintenance Manual 141 ...
Страница 147: ......