Goodrive3000 series medium voltage VFD
Goodrive3000 rectifier
-43-
The function codes are used to set IP addresses and subnet masks for Ethernet communication.
IP address format: P13.01.P13.02.P13.03.P13.04
IP address example: 192.168.0.1
Subnet mask format: P13.05.P13.06.P13.07.P13.08
Subnet mask example: 255.255.255.0
Function
code
Name
Description
Setting range
Default
P13.09
Gateway address 1 0
–255
0
–255
192
P13.10
Gateway address 2 0
–255
0
–255
168
P13.11
Gateway address 3 0
–255
0
–255
1
P13.12
Gateway address 4 0
–255
0
–255
1
The function codes are used to set gateways for Ethernet communication.
5.3 Fault information and fault handling
Fault
code
Fault type
Possible cause
Solution
OC
Input overcurrent
Incorrect current or voltage loop
parameter setting
Hardware circuit exception
Rectifier overload
Adjust the current or voltage loop
parameter setting.
Ask for technical support.
Adjust the load or select the rectifier
with larger power
Lv1
Input undervoltage
Abnormal input power outage
Input
voltage
detection
circuit
exception
Check the input power for recovery.
Ask for technical support.
Ov1
Input overvoltage
Input power exception
Interference
Input
voltage
detection
circuit
exception
Check the input power for recovery.
Check for and remove the external
interference source.
Ask for technical support.
SPI
Phase loss on input
side
Input power cable disconnection or
power exception
Power phase loss detection circuit
exception
Interference
Check the input power for recovery.
Ask for technical support.
Check for and remove the external
interference source.
PLLF
Phase lock failure
Grid environment exception, such as
the sudden change of grid frequency
or voltage
Grid voltage sampling board circuit
exception
Check
for
and
remove
the
interference source
Ask for technical support.
Lv
DC bus undervoltage
Input power exception
Bus
voltage
detection
circuit
exception
Interference
Check the input power for recovery.
Ask for technical support.
Check for and remove the external
interference source.
ov
DC bus overvoltage
Input power exception
Bus
voltage
detection
circuit
exception
Interference
Check the input power for recovery.
Ask for technical support.
Check for and remove the external
interference source.
ItE
Current detection
fault
Poor contact of the connector of
control board
Check the connector and re-plug
Ask for technical support.