Goodrive3000 series medium voltage VFD
Goodrive3000 inverter
-149-
Function
code
Name
Description
Setting
range
Default Modify
power-on
1: The terminal running
command is valid at power-on
P01.19
Action selected when
running frequency less than
frequency lower limit (valid
when frequency lower limit
greater than 0)
0: Run at the frequency lower
limit
1: Stop
2: Sleep
0
–2
0
◎
P01.20
Wake-up-from-sleep delay
0.0
–3600.0s
(valid
when
P01.19=2)
0.0
–3600.0
0.0s
○
P01.21
Power-off restart selection
0: Disable
1: Enable
0
–1
0
○
P01.22
Wait time for restart after
power-off
0.0
–3600.0s
(valid
when
P01.21=1)
0.0
–3600.0
1.0s
○
P01.23
Start delay
0.0
–60.0s
0.0
–60.0
0.0s
○
P01.24
Stop speed delay
0.0
–100.0 s
0.0
–100.0
0.0s
○
P01.25
0Hz output selection
0: Output without voltage
1: Output with voltage
2: Output with the DC braking
current for stop
0
–2
0
○
P02 group
––Parameters of motor 1
P02.00
Type of motor 1
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
–1
0
◎
P02.01
Rated power of AM 1
0.1
–3000.0kW
0.1
–3000.0
Model
depended
◎
P02.02
Rated frequency of AM 1
0.01Hz
–P00.03 (Max. output
frequency)
0.01
–P00.03 50.00Hz
◎
P02.03
Rated speed of AM 1
1
–36000rpm
1
–36000
Model
depended
◎
P02.04
Rated voltage of AM 1
0
–4000V
0
–4000
Model
depended
◎
P02.05
Rated current of AM 1
0.8
–6000.0A
0.8
–6000.0
Model
depended
◎
P02.06
Stator resistance of AM 1 0.001
–65.535Ω
0.001
–
65.535
Model
depended
○
P02.07
Rotor resistance of AM 1 0.001
–65.535Ω
0.001
–
65.535
Model
depended
○
P02.08 Leakage inductance of AM 1 0.1
–6553.5mH
0.1
–6553.5
Model
depended
○
P02.09
Mutual inductance of AM 1 0.1
–6553.5mH
0.1
–6553.5
Model
depended
○
P02.10
No-load current of AM 1
0.1
–6553.5A
0.1
–6553.5
Model
depended
○
P02.11
Magnetic saturation
coefficient 1 of iron core of
AM 1
0.0
–100.0%
0.0
–100.0
80.0%
○
P02.12
Magnetic saturation
coefficient 2 of iron core of
0.0
–100.0%
0.0
–100.0
68.0%
○