Goodrive3000 series medium voltage VFD
Goodrive3000 inverter
-169-
Function
code
Name
Description
Setting
range
Default Modify
depended
P08.09
Jump frequency 1
0.00Hz
–P00.03 (Max. output
frequency)
0.00
–P00.03 0.00Hz
○
P08.10 Jump frequency amplitude 1
0.00Hz
–P00.03 (Max. output
frequency)
0.00
–P00.03 0.00Hz
○
P08.11
Jump frequency 2
0.00Hz
–P00.03 (Max. output
frequency)
0.00
–P00.03 0.00Hz
○
P08.12 Jump frequency amplitude 2
0.00Hz
–P00.03 (Max. output
frequency)
0.00
–P00.03 0.00Hz
○
P08.13
Jump frequency 3
0.00Hz
–P00.03 (Max. output
frequency)
0.00
–P00.03 0.00Hz
○
P08.14 Jump frequency amplitude 3
0.00Hz
–P00.03 (Max. output
frequency)
0.00
–P00.03 0.00Hz
○
P08.15
–
P08.26
Reserved
P08.27
Set running time
0
–65535min
0
–65535
0min
○
P08.28
Auto fault reset count
0
–10
0
–10
0
○
P08.29
Auto fault reset interval
0.1
–3600.0s
0.1
–3600.0
1.0s
○
P08.30
Frequency decrease ratio in
drop control
0.00Hz
–50.00Hz
0.00
–50.00 0.00Hz
○
P08.31
Switching between motor 1
and motor 2
0: Terminal
1: MODBUS communication
2:
PROFIBUS/CANopen
communication
3: Ethernet communication
4: Reserved
0
–4
0
◎
P08.32
FDT1 electrical level
detection value
0.00Hz
–P00.03 (Max. output
frequency)
0.00
–P00.03 50.00Hz
○
P08.33
FDT1 lagging detection
value
0.0
–100.0% (FDT1 electrical
level)
0.0
–100.0
5.0%
○
P08.34
FDT2 electrical level
detection value
0.00Hz
–P00.03 (Max. output
frequency)
0.00
–P00.03 50.00Hz
○
P08.35
FDT2 lagging detection
value
0.0
–100.0% (FDT2 electrical
level)
0.0
–100.0
5.0%
○
P08.36
Detection value for
frequency being reached
0.0Hz
–P00.03
(Max.
output
frequency)
0.0
–P00.03 0.00Hz
○
P08.37
Enabling dynamic braking
0: Disable
1: Enable
0
–1
0
○
P08.38
Dynamic braking threshold
voltage
200.0
–6000.0V
200.0
–
6000.0
Model
depended
○
P08.39
Cooling-fan running mode
0: Normal mode
1: Permanent running after
power-on
0
–1
0
○
P08.40
Reserved
◎
P08.41
Overmodulation selection
0x0
–0x1
Ones place
0: Disable
0x0
–0x1
0x0
◎