Goodrive3000 series medium voltage VFD
Goodrive3000 inverter
-105-
Function
code
Name
Description
Setting range
Default
P08.38
Dynamic braking
threshold voltage
200.0
–6000.0V
200.0
–6000.0
Model
depended
The function code is used to set the starting bus voltage of energy consumption braking. Adjust this value properly to
achieve effective braking for the load. The default value varies depending on the voltage class.
The relationship between voltage and dynamic brake threshold voltage is as follows:
Model
Default dynamic braking threshold voltage
(P08.38)
Overvoltage point
660V
1100V
1200V
1140V
1950V
2150V
3300V
5500V
6000V
Function
code
Name
Description
Setting range
Default
P08.39
Cooling-fan running
mode
0: Normal mode
1: Run immediately after power-on
0
–1
0
The function code is used to set the running mode of the cooling fan.
0: Normal running mode: after the module receives the running command or the detection temperature of the rectifier is
higher than 45°C or the current of the module is higher than 20% of the rated current, the cooling fan will run.
1: Run immediately after power-on (applicable to high temperature and humidity situations only)
Function
code
Name
Description
Setting range
Default
P08.41
Overmodulation
selection
0: Disable
1: Enable
0
–1
0
The function code is used to enable the overmodulation function
Function
code
Name
Description
Setting range Default
P08.42
Keypad digit control
setting
0x0000
–0x1223
Ones place: Frequency setting selection
0: Controls through both the
∧
/
∨
key
and digital potentiometer are valid.
1: Only control through the
∧
/
∨
key is
valid.
2: Only control through the digital
potentiometer is valid.
3: Controls through the
∧
/
∨
key and
digital potentiometer are invalid.
Tens place: Frequency control selection
0: Valid only when P00.06=0 or P00.07=0
1: Valid for all frequency setting methods
2: Invalid for multi-step speed running
when multi-step speed running has the
priority
Hundreds place: Action selection for stop
0: Setting is valid.
1: Valid during running, cleared after stop
0x0000
–
0x1223
0x0000