SECTION 11—CONTROLLER
Zoom 300 and Zoom 400
82
Part No 1122167
Options Menu
NOTE: Options Menu settings are either ON or OFF.
To change the current setting of the options:
A. Press the VARY key to change the current setting.
B. Press the ENTER key to confirm the value when finished.
OPTIONS
FACTORY
DEFAULT
SETTING
RANGE
DESCRIPTION
1
ACCELERATION
3
1
Slowest acceleration to maximum forward speed.
10
Fastest acceleration to maximum forward speed.
2
DECELERATION
7
1
Slowest deceleration from maximum forward speed.
10
Fastest deceleration from maximum forward speed.
3
FORWARD SPEED
10
1
Slowest forward speed.
10
Fastest forward speed.
4
REVERSE SPEED
4
1
Slowest reverse speed.
10
Fastest reverse speed.
5
REDUCE SPEED
5
1
Slowest limit of maximum forward speed and maxi-
mum reverse speed.
10
Fastest limit of maximum forward speed and maxi-
mum reverse speed.
6
BUZZER VOLUME
10
1
Turns the horn/buzzer OFF.
2-10
Turns the horn/buzzer ON, 10 being the highest
volume setting.
7
SLEEP TIME
30
5
Fastest sleep time setting for the scooter (the
scooter powers down after 5 minutes of inactivity).
60
Slowest sleep time setting for the scooter (the
scooter powers down after 60 minutes of inactivity).
OPTIONS
FACTORY
DEFAULT
SETTING
RANGE
DESCRIPTION
1
POT REVERSE
OFF
ON
Polarity of the Throttle Potentiometer is reversed
(Left Hand Drive)
OFF
Normal polarity of the Throttle Potentiometer
(Right Hand Drive)
2
ENABLE SLEEP
ON
ON
Sleep time is enabled.
OFF
Sleep time is disabled.