Result
Test-specific string
Failed
System board
Action: Have the system serviced.
Function: PCI interface messages (020)
Result
Test-specific string
Note: If you receive any diagnostic error messages that are not shown in this table, make sure that
your server has the latest levels of BIOS, Advanced System Management Processor, and diagnostics
microcode installed. If the problem persists, have the system serviced.
Failed
System board
Action: Have the system serviced.
Failed
Tab on PCI Hot Swap slot #n is bad.
where n is the number of the failing PCI slot.
Action: Make sure the tab and latch on hot-plug PCI slot n are closed correctly.
Note: For normal operation, the Power LED for the hot-plug PCI slot is on, and the
Attention LEDs are off.
If the problem persists, have the system serviced.
Function: SCSI interface messages (030)
Result
Test-specific string
Note: If you receive any diagnostic error messages that are not shown in this table, make sure that
your server has the latest levels of BIOS, Advanced System Management Processor, and diagnostics
microcode installed. If the problem persists, have the system serviced.
Failed
SCSI adapter in slot n failed register/counter/power test
where n is the slot number of the failing adapter.
Action: Refer to the documentation provided with the adapter.
If the problem persists, have the system serviced.
Failed
SCSI controller on system board failed register/counter/power test
Action: Have the system serviced.
Function: RAID messages (035)
Result
Test-specific string
Note: If you receive any diagnostic error messages that are not shown in this table, make sure that
your server has the latest levels of BIOS, Advanced System Management Processor, and diagnostics
microcode installed. If the problem persists, have the system serviced.
Aborted
Test setup error: No ServeRAID adapter found on system board or PCI bus
Action: Have the system serviced.
Failed
Adapter in slot n; adapter/drive configuration error
where n is the slot number of the failing adapter.
Action:
1. Run the ServeRAID Configuration Utility program.
2. If the problem persists, replace the ServeRAID adapter in slot n.
If the problem persists, have the system serviced.
128
IBM xSeries User's Reference
Содержание eServer 240 xSeries
Страница 1: ...User s Reference xSeries 240...
Страница 26: ...16 IBM xSeries User s Reference...
Страница 50: ...40 IBM xSeries User s Reference...
Страница 116: ...106 IBM xSeries User s Reference...
Страница 170: ...160 IBM xSeries User s Reference...
Страница 180: ...170 IBM xSeries User s Reference...
Страница 219: ...IBM Part Number 21P9014 Printed in the United States of America 21P9 14...