Function: power supply messages (075)
Result
Test-specific string
Note: If you receive any diagnostic error messages that are not shown in this table, make sure that
your server has the latest levels of BIOS, Advanced System Management Processor, and diagnostics
microcode installed. If the problem persists, have the system serviced.
Failed
Voltage sensed by the system is out of range
Action: Have the system serviced.
Function: microprocessor error messages (089)
Result
Test-specific string
Note: If you receive any diagnostic error messages that are not shown in this table, make sure that
your server has the latest levels of BIOS, Advanced System Management Processor, and diagnostics
microcode installed. If the problem persists, have the system serviced.
Failed
Invalid microprocessor in socket id xyz or BIOS setup problem
where xyz identifies the microprocessor causing the error message.
Action:
1. Check the system error log for related error messages.
2. If your server does not have the latest level of BIOS installed, update the BIOS
to the latest level. Refer to Chapter 7, “Getting help, service, and information”
on page 161 for information about obtaining updates.
3. If the problem persists, replace the indicated microprocessor and run the
microprocessor diagnostic program again.
If the problem persists, have the system serviced.
Failed
Microprocessor in socket id xyz
where xyz identifies the microprocessor causing the error message.
Note: The Microprocessor Error LED associated with the microprocessor identified
is on. See “Processor-board component locations” on page 101 for the
location of the Microprocessor Error LEDs.
Action:
1. Reseat the microprocessor.
2. If the problem persists, replace the identified microprocessor.
If the problem persists, have the system serviced.
Failed
Processor in socket id xyz is defective
where xyz identifies the microprocessor that is causing the error message.
Action: Replace the microprocessor.
If the problem persists, have the system serviced.
Failed
Processor in socket id xyz is installed but not functioning
where xyz identifies the microprocessor causing the error message.
Action:
1. Check the system error log for related error messages.
2. If your server does not have the latest level of BIOS installed, update the BIOS
to the latest level. Refer to Chapter 7, “Getting help, service, and information”
on page 161 for information about obtaining updates.
3. If the problem persists, replace the microprocessor indicated and run the
microprocessor diagnostic program again.
If the problem persists, have the system serviced.
130
IBM xSeries User's Reference
Содержание eServer 240 xSeries
Страница 1: ...User s Reference xSeries 240...
Страница 26: ...16 IBM xSeries User s Reference...
Страница 50: ...40 IBM xSeries User s Reference...
Страница 116: ...106 IBM xSeries User s Reference...
Страница 170: ...160 IBM xSeries User s Reference...
Страница 180: ...170 IBM xSeries User s Reference...
Страница 219: ...IBM Part Number 21P9014 Printed in the United States of America 21P9 14...