POST message
Description
162
A change in device configuration occurred. This error occurs under one or more of
the following conditions:
A new device has been installed.
A device has been moved to a different location or cable connection.
A device has been removed or disconnected from a cable.
A device is failing and is no longer recognized by the server as being installed.
An external device is not turned on.
An invalid checksum is detected in the battery-backed memory.
Action: Verify that all external devices are turned on. You must turn on external
devices before turning on the server.
If you did not add, remove, or change the location of a device, a device is probably
failing. Running the diagnostic test programs might isolate the failing device, but
you must have the system serviced.
163
The time of day has not been set.
Action: Set the correct date and time. If the date and time are set correctly and
saved, but the 163 error message reappears, have the system serviced.
The server can be used until the system is serviced, but any application programs
that use the date and time will be affected.
164
A change in the memory configuration occurred. This message might appear after
you add or remove memory.
Note: The server can be used with decreased memory capacity.
Action:
1. If POST error message 289 also occurred, follow the instructions for that error
message first.
2. If you have installed or removed memory, run the Configuration/Setup Utility
program; then, exit, saving the new configuration settings. For information
about using the Configuration/Setup Utility program see “Using the
Configuration/Setup Utility main menu” on page 21.
If the message appears again, shutdown the server, reseat the memory
modules, and restart the server.
3. If the problem persists, check to see if the system has isolated the problem to a
memory module:
If the System Error light on the operator information panel is on, check to
see if the MEM LED on the diagnostic LED panel is on. If it is on, check
the DIMM Error LEDs next to the memory sockets on the processor board
(see “Processor-board component locations” on page 101). If a DIMM Error
LED is on, run the diagnostic program for the memory.
– If the tests fail, replace the DIMM. If the problem persists after you
replace the DIMM, have the system serviced.
– If the memory tests do not fail, have the system serviced.
If no error LED is on, the error logs in the Configuration/Setup Utility
program might provide additional information on the memory error.
If the problem persists, have the system serviced.
175
A vital product data (VPD) error occurred.
Action: Have the system serviced.
176
177
178
A security hardware error occurred.
Action: Check for indications that someone has tampered with the server. If no
one has tampered with the server, have the system serviced.
184
The power-on password information stored in your server has been removed.
Action: From the Configuration/Setup Utility program main menu, select System
Security. Then, follow the instructions on the screen. For information about using
the Configuration/Setup Utility program, see “Using the Configuration/Setup Utility
main menu” on page 21.
If this information cannot be restored, have the system serviced.
114
IBM xSeries User's Reference
Содержание eServer 240 xSeries
Страница 1: ...User s Reference xSeries 240...
Страница 26: ...16 IBM xSeries User s Reference...
Страница 50: ...40 IBM xSeries User s Reference...
Страница 116: ...106 IBM xSeries User s Reference...
Страница 170: ...160 IBM xSeries User s Reference...
Страница 180: ...170 IBM xSeries User s Reference...
Страница 219: ...IBM Part Number 21P9014 Printed in the United States of America 21P9 14...