Chapter 6. Using Diagnostics
You can invoke diagnostics for the IBM 2212 from OPCON prompt (*) when the
IBM 2212 is operating normally, or from the Service Recovery (
SVC>
) prompt when
the IBM 2212 is experiencing problems. You can run the IBM 2212 diagnostics
using the local terminal connection or from the Support Center using a remote
connection.
This chapter describes general procedures for invoking diagnostics and includes
sample panels.
Overview of Diagnostic Functions and Status Information
Diagnostics are available to test each adapter. In some cases, you may also be
able to test individual ports of multi-port adapters. These tests execute
concurrently with normal operation on other adapters and ports.
You can use the following types of diagnostic pages:
¹
Device List to show a summary list of devices
¹
Device Status and Control to allow you to disable and test a device
¹
Test Results to present the results of the test for a device.
¹
Test Options to allow you to choose specific testing options for a device.
¹
Setup for Loop Test to prompt for the presence of diagnostic aids such as
wrap plugs.
¹
The Restore from Loop Test to prompt you to remove diagnostic aids that
have been installed prior to testing
Many of the diagnostic pages have help information that provides definitions of the
status fields and testing options.
These diagnostics operate in a multi-tasking environment that allows several
diagnostic processes to be active at the same time. The Diagnostic Control
Program controls which test processes are active and which one has access to the
user interface.
When you make a selection from the Device Status and Control Page for a device,
a separate testing process is started that runs independently of the other diagnostic
menus. You can then go back to the Device List page or exit the diagnostic menus,
returning later to view the results of the test.
When an active test process wants to report results or obtain information from you,
the diagnostic status for the device will change to MESSAGE. When you select the
device on the Device List page, the testing process will be given access to the
console interface and the message will be displayed.
Note: It is necessary to “refresh” the Device List and Device Status and Control
pages in order to see the changing status of active test processes.
Copyright IBM Corp. 1998, 1999
6-1
Содержание Cloud Object Storage System Slicestor 2212...
Страница 1: ...2212 Access Utility Service and Maintenance Manual GY27 0362 02...
Страница 8: ...viii 2212 Service and Maintenance...
Страница 28: ...1 20 2212 Service and Maintenance...
Страница 86: ...3 8 2212 Service and Maintenance...
Страница 98: ...5 4 2212 Service and Maintenance...
Страница 110: ...Testing the Adapters 6 12 2212 Service and Maintenance...
Страница 112: ...Assembly 1 Final Assembly IBM 2212 Models 10x A 2 2212 Service and Maintenance...
Страница 114: ...Assembly 2 Final Assembly IBM 2212 Models 15x A 4 2212 Service and Maintenance...
Страница 116: ...Assembly 3 Final Assembly IBM 2212 Models 1xx A 6 2212 Service and Maintenance...
Страница 118: ...Assembly 4 Final Assembly IBM 2212 Models 1xx A 8 2212 Service and Maintenance...
Страница 120: ...Assembly 5 Final Assembly IBM 2212 Models 40x A 10 2212 Service and Maintenance...
Страница 122: ...Assembly 6 Final Assembly IBM 2212 Models 45x A 12 2212 Service and Maintenance...
Страница 124: ...Assembly 7 Final Assembly IBM 2212 Models 4xx A 14 2212 Service and Maintenance...
Страница 126: ...Assembly 8 Final Assembly IBM 2212 Models 4xx A 16 2212 Service and Maintenance...
Страница 130: ...A 20 2212 Service and Maintenance...
Страница 136: ...1 2 3 4 5 6 7 8 9 10 Figure C 1 AC Power Cord Plugs by Country C 4 2212 Service and Maintenance...
Страница 138: ...D 2 2212 Service and Maintenance...
Страница 166: ...E 28 2212 Service and Maintenance...
Страница 195: ......
Страница 197: ...Spine information 2212 Access Utility Service and Maintenance Manual...