008 (continued)
Does this correct the problem?
Yes No
009
|
Call 1-800-IBM-SERV (if outside the United States or Canada, contact the
|
local support organization for your country).
010
Restart the verification procedure. Go to Step 001 on page 1-9.
011
A yellow LED for an I/O port is on or blinking. Is the yellow LED blinking?
Yes No
012
– I/O port yellow LED is on. The adapter is defective. Replace it. (See
“Exchanging a CPCI Adapter” on page 2-10.) Restart the verification
procedure. Go to Step 001 on page 1-9.
013
– I/O port yellow LED is blinking
There is a network or IBM 2212 problem. Check the following in the order listed:
1. Verify that the cables are securely plugged in.
2. Check the status of the network and the software configuration for the interface:
a. Contact the network administrator and determine if the network is
experiencing problems.
b. At the command-line interface, check the errors being logged for the I/O
port interface and the status of the interface:
¹
To check the status of the interface, see “Displaying the Status of An
Interface” on page E-15.
For a more detailed status of the interface, at the GWCON (
+
) prompt,
use the network
interface# command to display network statistics for
the interface. Refer to the
Access Integration Services Software User’s
Guide and see the monitoring chapter associated with the network
interface.
¹
To view the errors being logged for the interface, access the
command-line interface’s error logging system (ELS) and display the
errors for the interface type. (See “Displaying the Error Logging System
(ELS) Messages for an Interface” on page E-7 to access the ELS.)
c. The adapter hardware (I/O drivers or receivers for example) could be
defective. Using the operational diagnostics, run an interactive test with a
wrap plug, if available, on the I/O port. See “Testing the Adapters” on
page 6-8 to run the diagnostics.
Correct any problem that you find. Restart the verification procedure. Go to Step
001 on page 1-9.
Chapter 1. Problem Determination
1-13
Содержание Cloud Object Storage System Slicestor 2212...
Страница 1: ...2212 Access Utility Service and Maintenance Manual GY27 0362 02...
Страница 8: ...viii 2212 Service and Maintenance...
Страница 28: ...1 20 2212 Service and Maintenance...
Страница 86: ...3 8 2212 Service and Maintenance...
Страница 98: ...5 4 2212 Service and Maintenance...
Страница 110: ...Testing the Adapters 6 12 2212 Service and Maintenance...
Страница 112: ...Assembly 1 Final Assembly IBM 2212 Models 10x A 2 2212 Service and Maintenance...
Страница 114: ...Assembly 2 Final Assembly IBM 2212 Models 15x A 4 2212 Service and Maintenance...
Страница 116: ...Assembly 3 Final Assembly IBM 2212 Models 1xx A 6 2212 Service and Maintenance...
Страница 118: ...Assembly 4 Final Assembly IBM 2212 Models 1xx A 8 2212 Service and Maintenance...
Страница 120: ...Assembly 5 Final Assembly IBM 2212 Models 40x A 10 2212 Service and Maintenance...
Страница 122: ...Assembly 6 Final Assembly IBM 2212 Models 45x A 12 2212 Service and Maintenance...
Страница 124: ...Assembly 7 Final Assembly IBM 2212 Models 4xx A 14 2212 Service and Maintenance...
Страница 126: ...Assembly 8 Final Assembly IBM 2212 Models 4xx A 16 2212 Service and Maintenance...
Страница 130: ...A 20 2212 Service and Maintenance...
Страница 136: ...1 2 3 4 5 6 7 8 9 10 Figure C 1 AC Power Cord Plugs by Country C 4 2212 Service and Maintenance...
Страница 138: ...D 2 2212 Service and Maintenance...
Страница 166: ...E 28 2212 Service and Maintenance...
Страница 195: ......
Страница 197: ...Spine information 2212 Access Utility Service and Maintenance Manual...