Ref. code
Function Description
Setting Range [Default]
3: Three-wire running mode 2.
•
If SB2 changes from enabled into disabled, HD3N will keep the same mode.
•
Three-wire running mode: DI terminal is defined as No. 4 function.
F15.17
Action selection when extrenal device has fault
0 - 3 [0]
Protection action when external device has fault.
0: Coast to stop.
1: Emergency stop.
2: Decelerate to stop.
3: Continue to run.
F15.18
DO1 function
0 - 36 [2]
F15.19
DO2 function
0 - 38 [0]
F15.20
RLY1 relay function
0 - 36 [31]
0: Unused.
1: Inverter is ready.
•
HD3N completes power on and no fault occurs, then it can normally run.
2: Inverter running. HD3N is in run status.
3: Forward running. HD3N is forward running.
4: Reverse running. HD3N1 is reverse running.
5: DC brake. HD3N is DC brake.
6: Zero-frequency status.
•
In zero-frequency range, the output frequency (including in stop status) outputs.
•
Refer to F15.28 and F15.29.
7: Zero-frequency running.
•
HD3N output frequency is within zero-frequency range.
•
Refer to F15.28 and F15.29.
9,10: Frequency level detection signal (FDT1,FDT2).
•
Refer to F15.31 - F15.35.
11: Frequency within FAR range (FAR).
•
The output frequency is within FAR range.
•
Detection range is set by F15.27.
12: Frequency upper limit.
•
Indicating signal will output when setting frequency ≥ upper limit frequency.
13: Frequency lower limit.
•
Indicating signal will output when setting frequency ≤ lower limit frequency.
COM
F15.16=2
F15.16=3
P24
SEL
DIx
DIz
DIy
COM
P24
SEL
DIx
DIz
DIy
SB2
SB2
SB3
K
SB1
SB1
FWD
FWD / REV
RUN
REV
SB1: Normally closed stop button
SB2: Normally open forward button
SB3: Normally open reverse button
K: Direction selection terminal (level on)
K = 0(forward) K = 1(reverse)
SB1: Normally closed stop button
SB2: Normally open run button
Three-wire
Three-wire
6