Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
- 54 -
HD3N Series User Manual V1.1
6.2.3
F02: Parameters for Start and Stop
Ref. code
Function Description
Setting Range [Default]
F02.00
Start mode
0 - 2 [0]
In torque control mode, the setting of start mode is invalid.
0: Start from starting DWELL frequency.
•
Refer to F02.02 and F02.03 for starting DWELL frequency.
1: Brake and then start from starting DWELLfrequency.
•
Refer to F02.04 and F02.05 for DC brake.
•
The starting DC brake is valid only during process of stop status switching to running status. It is invalid
when FWD and REV reversed during running. Refer to bolow figure F02.05 (DC brake starting time) is
invalid).
2: Rotate speed tracking re-start. When the result is lower than F02.02, HD3N starts from starting DWELL
frequency.
•
Tracks the rotate speed and direction of motor automatically,smooth and low impact is applied to
motor which is rotating.
•
Rotate speed tracking is valid only during the process of switching from stop to running. It is invalid
during running when the direction switches.
F02.01
Start delay time
0.00 - 10.00 [0.00s]
On receiving run conmand, HD3N will wait until F02.01 is finished and run.
Forward
Reverse
Time
Frequency
F02.01
F02.02
F02.02
0
F02.03
F00.19
F02.03
F02.03
Forward
Reverse
Time
Frequency
F02.01 F02.05
F02.02
F02.02
0
F02.03
F00.19
Motor rotation
Inverter running
command
Inverter running
frequency
Inverter running
direciton
0
Motor free rotaiton
Oppositive direction
Positive direction
Recognize motor speed
and direction
Rotation setting
Frequency setting