Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd.
- 112 -
HD3N Series User Manual V1.1
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
d00.17
Setting rpm (rpm)
0 - 60000rpm
*
d00.18
Runnig rpm (rpm)
0 - 60000rpm
*
d00.19
Input voltage (V)
0 - 999V
*
d00.20
Output voltage (V)
0 - 999V
*
d00.21
Output current (A)
Actual value, unit: 0.1A
*
d00.22
Torque setting (%)
-250.0 - 250.0% (rated torque of
motor)
*
d00.23
Output torque (%)
0.0 - 300.0% (rated torque of motor)
*
d00.24
Output power (kW)
Actual value, unit: 0.1kW
*
d00.25
DC busbar voltage (V)
0 - 999V
*
d00.26
Input voltage of
potentionmeter (%)
0.0 - 100.0%
Valid when LED keypad adopted
*
d00.27
AI1 input (%)
0.0 - 100.0%
*
d00.28
AI1 input (after
calculating) (%)
0.0 - 100.0%
*
d00.29
AI2 input (%)
0.0 - 100.0%
*
d00.30
AI2 input (after
calculating) (%)
0.0 - 100.0%
*
d00.35
DI6 terminal pulse input
frequency (Hz)
0 - 10000Hz
*
d00.36
AO1 output (%)
0.0 - 100.0%
*
d00.37
AO2 output (%)
0.0 - 100.0%
*
d00.38
High speed output pulse
frequency (Hz)
0 - 10000Hz
*
d00.40
Setting line speed
0 - max output line speed
*
d00.41
Reference line speed
0 - max output line speed
*
d00.44
PID setting (%)
-100.0 - 100.0%
*
d00.45
PID feedback (%)
-100.0 - 100.0%
*
d00.46
PID tolerance (%)
-100.0 - 100.0%
*
d00.47
PID integral item (%)
-100.0 - 100.0%
*
d00.48
PID output (%)
-100.0 - 100.0%
*
d00.49
External count value
0 - 9999
*
d00.50
Input terminal status
Bit0 - Bit8 correspond to DI1 - DI6
0: Input terminals disconnect with
common terminals
1: Input terminals connect with
common terminals
*
d00.51
Output terminal status
Bit0 - Bit1 correspond to DO1 - DO2
Bit2 correspond to RLY1
0: Output terminals disconnect with
common terminals
1: Output terminals connect with
common terminals
*