Appendix B Communication Protocol
Shenzhen Hpmont Technology Co., Ltd.
- 148 -
HD3N Series User Manual V1.1
Control command (0x3200) and its setting:
Control (Bit)
Meaning
Description
Bit0
0: Running
command is invalid
1: Running commandi s
valid
Control start and stop (Edge trigger)
Bit1
0: FWD
1: REV
Control running direction
Bit2
0: Unused
1: Coast to stop
Control stop mode (Edge trigger)
Bit3
0: Unused
1: Emergency to stop
Control stop mode (Edge trigger)
Bit4
0: Unused
1: Coast to stop
Control stop mode (Edge trigger)
Bit5
0: Unused
1: Eexternal fault signal
Display external fault and stop or run
according to F17.08
Bit6
0: Stop jog FWD
1: Jog FWD
Control jog FWD
Bit7
0: Stop jog REV
1: Jog REV
Control jog REV
Bit8
0: Fault reset is
invalid
1: Fault reset is valid
Control fault reset
Bit9 - Bit11
0: Unused
Bit12
0: Current control is
invalid
1: Current control is valid
Control is valid/invalid
Bit13 - Bit15
0: Unused
Register content can control command:
Register content
Control command
Register address
Parameter name
0x1001
RFWD
0x1020
Stop due to external fault
0x1003
REV
0x1040
Jog FWD
0x1004
Dec to stop
0x1080
Jog REV
0x1008
Emergency to stop
0x1100
Fault reset
0x1010
Coast to stop
Virtual terminal control setting (0x3204) and its setting:
Control (Bit)
Meaning
Bit0
0: DO1 output is invalid
1: DO1 output is valid
Bit1
0:DO2 output is invalid
1: DO2 output is valid
Bit2
0: RLY1 output is invalid
1: RLY1 output is valid
Bit3 - Bit15
Unused
Unused