Technical Data / Information
23.14 Tissue-Doppler
TD Mode:
Tissue mode flow imaging is only possible with phased array probes.
Display modes:
2D/TD (Single, Dual, Quad); 2D+2D/TD
TD coding steps:
8192 color steps
Depth range:
axial: 0 to B-scan range
lateral: 0 to B-scan-range
Zero line shift:
17 steps
Inversion of color direction:
yes
Smoothing Filter:
12 steps rising time
12 steps falling time
Gain control :
30dB
Density (color line density):
9 steps
Ensemble (color shots per line): 7 to 31
Pulse repetition frequency:
100 Hz to 11 kHz
TD Map:
4 different color codes for each probe
Frequency range:
1 to 15 MHz depending on the probe,
adjustable in 3 steps (low, mid, high)
Balance:
from 25 to 225 in 41 steps
Max. meas. velocity:
5.0 m/sec.
Min. meas. velocity:
0.3 cm/sec.
Display Mode:
V (velocity)
Scale:
kHz, cm/s, m/s
23.15 Power-Doppler
PD Mode:
Power-Doppler imaging is possible with curved array, linear array and phased array probes.
Display modes:
2D/PD (Single, Dual, Quad); 2D+2D/PD
Simultaneous triplex mode: 2D/PD+/D
3D/PD
PD coding steps:
256 color steps
PD window size:
lateral: maximum to minimum 2D mode scan angle
axial: 0 B-scan range
Display mode:
P (power)
Wall motion Filter:
7 steps
Smoothing Filter:
rising edge: 12 steps
falling edge: 12 steps
Gain control :
30dB
PD display ensemble:
7 to 31
PD display density
:
9 steps
Pulse repetition frequency:
100 Hz to 11kHz
PD Map:
8 different color codes for each probe
Frequency range:
1 to 15 MHz depending on the probe,
adjustable in 3 steps (low, mid, high)
Image sequence memory:
max. 128 images, 1024 images optional
Balance:
from 25 to 225 in 41 steps
Artifact suppression:
yes
Voluson
®
730Pro - Operation Manual
105831 Rev. 0
23-11
Содержание Voluson 730Pro
Страница 1: ... B BA AS SI IC C U US SE ER R M MA AN NU UA AL L GE Medical Systems Kretztechnik GmbH Co OHG ...
Страница 4: ...This page intentionally left blank Voluson 730Pro Operation Manual i 2 105831 Rev 0 ...
Страница 22: ...CONTENTS This page intentionally left blank Voluson 730Pro Basic User Manual 18 CONTENTS 105831 Rev 0 ...
Страница 23: ...General 1 General 1 2 Voluson 730Pro Basic User Manual 105831 Rev 0 1 1 ...
Страница 44: ...Safety This page intentionally left blank Voluson 730Pro Basic User Manual 2 20 105831 Rev 0 ...
Страница 112: ...2D Mode This page intentionally left blank Voluson 730Pro Basic User Manual 5 22 105831 Rev 0 ...
Страница 172: ...PD Mode This page intentionally left blank Voluson 730Pro Basic User Manual 9 14 105831 Rev 0 ...
Страница 262: ...Volume Mode This page intentionally left blank Voluson 730Pro Basic User Manual 11 78 105831 Rev 0 ...
Страница 290: ...Basic Measurements This page intentionally left blank Voluson 730Pro Basic User Manual 13 16 105831 Rev 0 ...
Страница 411: ...Biopsy Setup 19 Biopsy Setup 19 2 19 1 To Program a Biopsy Line 19 3 Voluson 730Pro Basic User Manual 105831 Rev 0 19 1 ...
Страница 414: ...Biopsy Setup This page intentionally left blank Voluson 730Pro Basic User Manual 19 4 105831 Rev 0 ...
Страница 442: ...Probes and Biopsy This page intentionally left blank Voluson 730Pro Basic User Manual 20 28 105831 Rev 0 ...
Страница 446: ...Connections 21 2 1 Main Module Voluson 730Pro Basic User Manual 21 4 105831 Rev 0 ...
Страница 458: ...Connections 21 2 11 ECG preamplifier MAN Connection Voluson 730Pro Basic User Manual 21 16 105831 Rev 0 ...