Volume Mode
Shell outside
•
The outside surface is the surface geometry of the outer 'parallel' contours with
distance
Shell
Thickness
in mm.
•
The inside surface is equal to the reference surface geometry.
Shell symmetric
•
The outside surface is the surface geometry of the outer 'parallel' contours with
half distance
Shell
Thickness
in mm.
•
The inside surface is the surface geometry of the inner 'parallel' contours with
half distance
Shell
Thickness
in mm.
If one of the inside contours is not valid, the inside surface is represented by an inner point (the inside
surface is degenerated). (A contour is only valid if the rotation axis is crossed exactly twice.)
The thickness of the shell can be adjusted by using this digipot control.
To activate the selected shell thickness press the digipot control.
Then the new shell thickness is calculated.
The shell contour is not accepted and you return to the VOCAL- ROI
Mode menu, where you can define a new contour.
The shell contour is accepted and stored.
The VOCAL - 3D Static menu appears in the menu area on the monitor.
Of course, only valid reference contours generate a valid shell contour
.
Display of the (Shell) Volume
The (shell) volume is defined as the difference between the volume defined by the outer surface
(of the shell geometry) and the volume defined by the inner surface (of the shell geometry).
A degenerated surface is symbolized in the display with xxxxx.
The Volume is displayed on the monitor in the lower right quadrant:
Shell xxx.xx cm³
Vref.
xxx.xx
cm³
Inside
xxx.xx
cm³
Outside
xxx.xx
cm³
If the reference surface geometry is not valid, all volumes are invalid and displayed with xxxxx.
Voluson
®
730Pro - Basic User Manual
105831 Rev. 0
11-73
Содержание Voluson 730Pro
Страница 1: ... B BA AS SI IC C U US SE ER R M MA AN NU UA AL L GE Medical Systems Kretztechnik GmbH Co OHG ...
Страница 4: ...This page intentionally left blank Voluson 730Pro Operation Manual i 2 105831 Rev 0 ...
Страница 22: ...CONTENTS This page intentionally left blank Voluson 730Pro Basic User Manual 18 CONTENTS 105831 Rev 0 ...
Страница 23: ...General 1 General 1 2 Voluson 730Pro Basic User Manual 105831 Rev 0 1 1 ...
Страница 44: ...Safety This page intentionally left blank Voluson 730Pro Basic User Manual 2 20 105831 Rev 0 ...
Страница 112: ...2D Mode This page intentionally left blank Voluson 730Pro Basic User Manual 5 22 105831 Rev 0 ...
Страница 172: ...PD Mode This page intentionally left blank Voluson 730Pro Basic User Manual 9 14 105831 Rev 0 ...
Страница 262: ...Volume Mode This page intentionally left blank Voluson 730Pro Basic User Manual 11 78 105831 Rev 0 ...
Страница 290: ...Basic Measurements This page intentionally left blank Voluson 730Pro Basic User Manual 13 16 105831 Rev 0 ...
Страница 411: ...Biopsy Setup 19 Biopsy Setup 19 2 19 1 To Program a Biopsy Line 19 3 Voluson 730Pro Basic User Manual 105831 Rev 0 19 1 ...
Страница 414: ...Biopsy Setup This page intentionally left blank Voluson 730Pro Basic User Manual 19 4 105831 Rev 0 ...
Страница 442: ...Probes and Biopsy This page intentionally left blank Voluson 730Pro Basic User Manual 20 28 105831 Rev 0 ...
Страница 446: ...Connections 21 2 1 Main Module Voluson 730Pro Basic User Manual 21 4 105831 Rev 0 ...
Страница 458: ...Connections 21 2 11 ECG preamplifier MAN Connection Voluson 730Pro Basic User Manual 21 16 105831 Rev 0 ...