
Index
LOGIQ 500 Basic Users Manual
2276612–100 Rev. 0
Index 16
Measurement,
3–43, 7–3
Accuracy,
16–5
Cursors,
7–4
Key,
7–5
Measurement Clear Operation [EC], Preset Program
menu page 3,
14–74
Measurement Menu B [EC, UP], Preset Program
menu page 7,
14–88
Measurement Menu CFM [EC, UP], Preset Program
menu page 7,
14–88
Measurement Menu D [EC, UP], Preset Program
menu page 7,
14–88
Measurement Menu M [EC, UP], Preset Program
menu page 7,
14–88
Measurements
Abdomen/Small Parts
A/B Ratio,
8–3, 10–29
Pulsatility Index (PI),
8–3, 10–29
Resistance Index (RI),
8–3, 10–29
S/D Ratio,
8–3, 10–29
B–Mode
Circumference/Area,
7–10
Distance,
7–7
Echo Level,
7–11
Bi Plane Ellipsoid Method,
10–17
Bullet Method,
10–11
Calculations,
7–6
Cardiology
% Stenosis,
10–23
Angle,
10–22
ET,
10–25
MVA,
10–24
PHT,
10–24
Volume,
10–19
Color Flow
Distance,
7–12
Echo Level (gray scale),
7–12
Ellipse/Trace,
7–12
Velocity Point.
See General Calculations
Controls,
7–3
Cubed Method,
10–7
Doppler
Peak Velocity,
7–14
TAMAX/TAMIN/TAMEAN/TAMODE,
7–15
General,
7–1
GYN,
9–43, 9–44
Endometrium Thickness,
9–45
Ovarian Height,
9–43
Ovarian Length,
9–43
Ovarian Width,
9–43
Ovary Follicles,
9–44
RI,
9–46
Uterine Height,
9–44
Uterine Length,
9–44
Uterine Width,
9–44
M–Mode
Depth Difference,
7–22
Time,
7–18, 7–21
Tissue Depth,
7–20
Modified Simpson’s Rule Method,
10–13
OB
A/B Ratio,
9–24
AFI,
9–20
D/S Ratio,
9–24
GS,
9–19
Hints,
9–24
HR,
9–24
Locatn,
9–23
Programmable User Table,
14–80
Pulsatility Index (PI),
9–24
Resistance Index (RI),
9–24
S/D Ratio,
9–24
Trace Auto,
9–24
Radiology/Abdomen.
See General Calculations
Single Plane Ellipsoid Method,
10–15
Small Parts.
See General Calculations
Teichholz Method,
10–9
Urology.
See General Calculations
Vascular,
11–3
A/B Ratio,
11–5
Heart Rate,
11–5
Pulsatility Index (PI),
11–5
Resistance Index (RI),
11–5
RT(LT) Bifurc,
11–3
RT(LT) CCA,
11–3
RT(LT) ECA,
11–3
RT(LT) ICA,
11–3
RT(LT) ICA/CCA,
11–4
S/D Ratio,
11–5
Volume,
10–19
Media Selection for Fetal Trend [EC], Preset
Program menu page 3,
14–74
Memory
Cine,
6–9
Image,
13–2
Storage Space,
13–2
Image Recall,
13–4
Menu Selection at New Patient, System Parameters
menu page 7,
14–67
Mic,
3–45
MIC (Multi–Image Camera),
13–17
Содержание 500
Страница 1: ... ...
Страница 58: ...Safety Precautions LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 2 28 This page left blank intentionally ...
Страница 104: ...Operator Controls LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 3 46 This page left blank intentionally ...
Страница 112: ...Exam Applic Preset Selection LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 4 8 This page left blank intentionally ...
Страница 262: ...General Calculations LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 8 12 This page left blank intentionally ...
Страница 312: ...GYN Summary Report LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 9 50 This page left blank intentionally ...
Страница 350: ...Advanced Cardiac Calculations LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 10 38 This page left blank intentionally ...
Страница 364: ...Urology Basic Calculations LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 12 4 This page left blank intentionally ...
Страница 404: ...Advanced Recording Option LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 13 40 This page left blank intentionally ...
Страница 610: ...Assistance LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 16 44 This page left blank intentionally ...