
Recording Images
LOGIQ 500 Basic Users Manual
2276612–100 Rev. 0
13–32
Patient Search (cont’d)
Searching the MOD
The search function is initiated when the Trackball is used to
move the highlighted cursor out of the criteria area or the
Return key is pressed while in the Date entry area.
The first 15 files are displayed on the monitor. If the search is
not complete, the message:
“In Progress, Please wait”
appears at the bottom of the monitor. This message remains
until the search process is totally complete.
NOTE: Images which are not stored on the GE LOGIQ
series systems will not be listed by the patient search function
or displayed on a LOGIQ
series machine.
In order to perform any other function, the user must wait until
the search is complete or press Ctrl, C simultaneously to
cancel the search function.
If no search criteria was entered by the user, a complete file
listing of the entire MOD is executed. Only 15 files are
displayed at one time on the monitor.
Use the top or bottom of the Ellipse rocker switch to scroll to
the next or previous patient list page.
Copy an image
To copy an image from the HD (MO) to MO (HD):
1.
Select the image to copy by pressing the Set key.
Multiple images can be selected.
2.
Move the cursor to the Image Copy column.
3.
Press the Set key. The image is copied to the MO (HD)
from HD (MO).
4.
Move the cursor to List All and press the Set key to
reflect the copied image in the Image Archive Patient
Search Menu.
The following message is displayed if the capacity of the HD or
MO is not enough for an image to be copied.
Too much data. Copy Failed.
Hints
Содержание 500
Страница 1: ... ...
Страница 58: ...Safety Precautions LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 2 28 This page left blank intentionally ...
Страница 104: ...Operator Controls LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 3 46 This page left blank intentionally ...
Страница 112: ...Exam Applic Preset Selection LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 4 8 This page left blank intentionally ...
Страница 262: ...General Calculations LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 8 12 This page left blank intentionally ...
Страница 312: ...GYN Summary Report LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 9 50 This page left blank intentionally ...
Страница 350: ...Advanced Cardiac Calculations LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 10 38 This page left blank intentionally ...
Страница 364: ...Urology Basic Calculations LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 12 4 This page left blank intentionally ...
Страница 404: ...Advanced Recording Option LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 13 40 This page left blank intentionally ...
Страница 610: ...Assistance LOGIQ 500 Basic Users Manual 2276612 100 Rev 0 16 44 This page left blank intentionally ...