Name
Function
Digital
input
(1)
Control
word
Digital
output
Status
word
Vir. master on ref.
The virtual master is running on the set reference
–
–
x
x
Execution distance ex-
tended
The offset execution distance set in
parameter 17-95 Off-
set Execution Distance
has been extended due to speed/
ramp limitation.
–
–
–
x
Pos. set acknowledge
The set target position has been activated.
–
–
x
x
1
For best accuracy, use fast digital inputs 18, 32, and 33 for home and touch probe sensors.
When
[3] FC Motion Profile
is selected in
parameter 8-10 Control Word Profile
, the bits in the control word and the status word have
the following meaning:
Table 1432: Control Word
Bit
0
1
0
Preset reference LSB
–
1
Preset reference MSB
–
2
(1)
Preset reference EXB
–
3
Coast stop
No coast stop
4
Quick stop
No quick stop
5
(1)
No reference
Enable reference
6
Ramp stop
Start
7
No reset
Reset
8
No jog
Jog
9
(1)
Absolute
Relative
10
Data not valid
Data valid
11
(1)
No homing
Start homing
12
(1)
No touch
Activate touch
AU275636650261en-000101 / 130R0334
688 | Danfoss A/S © 2022.12
Integrated Motion Controller
VLT AutomationDrive FC 301/302
Programming Guide