Parameter 30-05 Wobble Jump Frequency [%]
Table 1068: Parameter 30-05 Wobble Jump Frequency [%]
30-05 Wobble Jump Frequency [%]
Default value: 0%
Parameter type: Range, 0 - 100 %
Setup: All setups
Conversion index: 0
Data type: Uint8
Change during operation: True
The jump frequency can also be expressed as a percentage of the center frequency. The function is the same as for
parameter 30-04
Wobble Jump Frequency [Hz]
.
Parameter 30-06 Wobble Jump Time
Table 1069: Parameter 30-06 Wobble Jump Time
30-06 Wobble Jump Time
Default value: Size related
Parameter type: Range, 0.005 - 5.000 s
Setup: All setups
Conversion index: -3
Data type: Uint16
Change during operation: True
This parameter determines the slope of the jump ramp at the maximum and minimum wobble frequency.
Parameter 30-07 Wobble Sequence Time
Table 1070: Parameter 30-07 Wobble Sequence Time
30-07 Wobble Sequence Time
Default value: 10 s
Parameter type: Range, 1 - 1000 s
Setup: All setups
Conversion index: -1
Data type: Uint16
Change during operation: True
This parameter determines the wobble sequence period. This parameter can only be changed in stop mode.
Wobble time =
t
up
+
t
down
Parameter 30-08 Wobble Up/Down Time
Table 1071: Parameter 30-08 Wobble Up/Down Time
30-08 Wobble Up/Down Time
Default value: 5 s
Parameter type: Range, 0.1 - 1000 s, Array [2]
Setup: All setups
Conversion index: -1
Data type: Uint16
Change during operation: True
Defines the individual up and down times for each wobble cycle.
Parameter 30-09 Wobble Random Function
Table 1072: Parameter 30-09 Wobble Random Function
30-09 Wobble Random Function
Default value: [0] Off
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: True
Option
Name
Description
[0]*
Off
[1]
On
AU275636650261en-000101 / 130R0334
578 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide